Bộ điều khiển nhiệt độ 822E-8BS-6S-6S-W050-QC1 United Electic Controls 822E-8BS-10S-10S-W050-QC1 (10 feet cable)
type temperature
Type 800 - Bulb and capillary; one SPDT output; external indication
Type 802 - Bulb and capillary; two SPDT outputs; external indication
Type 820E - Bulb and capillary; one SPDT output; external indication, explosion proof
Type 822E - Bulb and capillary; two SPDT outputs; external indication, explosion proof
Type T800 - Bulb and capillary; thermometer only with external indication
options
switch Options* Description
0140 Gold contacts, 1 A 125 VAC resistive. NOT AVAILABLE TYPE 800, 820E, T800
0500 Close deadband, 5 A 125/250 VAC resistive. NOT AVAILABLE TYPE T800
1070 10 A 125 VDC or VAC resistive; deadband and minimum set point may increase. NOT AVAILABLE
TYPES 802, 820E, T800
2000 20 A 125/250 VAC resistive. NOT AVAILABLE TYPE T800
other Options
M007 Drilled 7/8” electrical opening on right side. NOT AVAILABLE TYPES 820E, 822E and T800
M100 Terminal block wiring. NOT AVAILABLE TYPE 820E, 822E (standard) AND T800
M201 Factory set one switch; specify increasing or decreasing temperature and set point. NOT AVAILABLE
TYPE 802, 822E, T800
M202 Factory set two switches; specify increasing or decreasing temperature and set point. Not available
type 800, 820E, t800
M300 Enclosure Type 4 construction; includes watertight conduit fitting and gasketing. NOT AVAILABLE
TYPES 820E, 822E (which already meet enclosure type 4X)
M320 Tamper resistant cover. NOT AVAILABLE TYPES T800
M404 Flameproof compliance for Ukraine per Gosnadzorohrantruda standards. NOT AVAILABLE TYPES 800,
802, T800
M406 Flameproof compliance for Russia per Rostechnadzor permit (RTN). NOT AVAILABLE TYPES 800, 802,
T800
M408 Flameproof compliance for China per CQST standards. NOT AVAILABLE TYPES 800, 802, T800
M444 Paper ID tag
M446 Stainless steel ID tag & wire attachment; limited to 2 lines of 25 characters each max.
M550 Oxygen service cleaning; alcohol cleaning to remove residue from the process connection
M900 Watertight conduit fitting; converts 7/8” hole to 1/2” NPT fitting. NOT AVAILABLE TYPES 820E,
822E, T800
* All switch options have limited DC capabilities. DC ratings are not listed on nameplate. Consult factory for details
UNION CONNECTORS**
Option Replacement Number Description
Brass
W027 SD6213-27 1⁄2” NPT w/ 3⁄4” bushing
W045 SD6213-45 3⁄4” NPT
W051 SD6213-51 1⁄2” NPT
304 Stainless Steel
W028 SD6213-28 1⁄2” NPT w/ 3⁄4” bushing
W046 SD6213-46 3⁄4” NPT
W050 SD6213-50 1⁄2” NPT
THERMOWELLS**
For all bulb & capillary switches
Brass
W075 SD6225-75 1⁄2” NPT with 3⁄4” NPT adapter bushing, 4” BT
W191 SD6225-191 1⁄2” NPT, 4” BT
W118 SD6225-118 1⁄2” NPT with 3⁄4” NPT adapter bushing, 7” BT
W192 SD6225-192 1⁄2” NPT, 7” BT
316 Stainless Steel
W076 SD6225-76 3⁄4” NPT, 4.5” BT
W193 SD6225-193 1⁄2” NPT, 4.5” BT
W119 SD6225-119 3⁄4” NPT, 7.5” BT
W177 SD6225-177 1⁄2” NPT, 7.5” BT
OPTIONAL LENGTHS:
Optional capillary length to 50’ may be available in 304 st/st. Armor or Teflon® capillary protection may be
available to lengths less than or equal to capillary length. Consult UE for additional information and availability.
Consult UE regarding repeatability and ambient effects on capillary lengths over 30’
**Dimensional drawings for union connectors and thermowells may be found at www.ueonline.com