Bộ truyền động van Schischek Schischek InMax Size M :InMax-50.75 InMax- 100 InMax- 150 InMax-50.75-S InMax- 100-S InMax- 150-S InMax-50.75-Y InMax- 100-Y
.png)
| Type | Torque | Running time 90° | Spring-return | Control mode | Feedback | Features | Size |
|---|---|---|---|---|---|---|---|
| InMax-50.75 | 50 Nm / 75 Nm | 40/60/90/120/150 sec. | – | On-off, 3-pos | – | – | M |
| InMax- 100 | 100 Nm | 40/60/90/120/150 sec. | – | On-off, 3-pos | – | – | M |
| InMax- 150 | 150 Nm | 40/60/90/120/150 sec. | – | On-off, 3-pos | – | – | M |
| InMax-50.75-S | 50 Nm / 75 Nm | 40/60/90/120/150 sec. | – | On-off, 3-pos | 2 × aux. switches (5°/85°) | – | M |
| InMax- 100-S | 100 Nm | 40/60/90/120/150 sec. | – | On-off, 3-pos | 2 × aux. switches (5°/85°) | – | M |
| InMax- 150-S | 150 Nm | 40/60/90/120/150 sec. | – | On-off, 3-pos | 2 × aux. switches (5°/85°) | – | M |
| InMax-50.75-Y | 50 Nm / 75 Nm | 40/60/90/120/150 sec. | – | 3-pos, 0...10 VDC, 4...20 mA | 0...10 VDC, 4...20 mA | – | M |
| InMax- 100-Y | 100 Nm | 40/60/90/120/150 sec. | – | 3-pos, 0...10 VDC, 4...20 mA | 0...10 VDC, 4...20 mA | – | M |
| Type | Torque | Running time 90° | Spring-return | Control mode | Feedback | Features | Size |
|---|---|---|---|---|---|---|---|
| InMax-30- F | 30 Nm | 40/60/90/120/150 sec. | ~ 20 sec. | On-off, 3-pos | – | – | M |
| InMax-50- F | 50 Nm | 40/60/90/120/150 sec. | ~ 20 sec. | On-off, 3-pos | – | – | M |
| InMax-60- F | 60 Nm | 40/60/90/120/150 sec. | ~ 20 sec. | On-off, 3-pos | – | – | M |
| InMax-30-SF | 30 Nm | 40/60/90/120/150 sec. | ~ 20 sec. | On-off, 3-pos | 2 × aux. switches (5°/85°) | – | M |
| InMax-50-SF | 50 Nm | 40/60/90/120/150 sec. | ~ 20 sec. | On-off, 3-pos | 2 × aux. switches (5°/85°) | – | M |
| InMax-60-SF | 60 Nm | 40/60/90/120/150 sec. | ~ 20 sec. | On-off, 3-pos | 2 × aux. switches (5°/85°) | – | M |
| InMax-30-YF | 30 Nm | 40/60/90/120/150 sec. | ~ 20 sec. | 3-pos, 0...10 VDC, 4...20 mA | 0...10 VDC, 4...20 mA | – | M |
| InMax-50-YF | 50 Nm | 40/60/90/120/150 sec. | ~ 20 sec. | 3-pos, 0...10 VDC, 4...20 mA | 0...10 VDC, 4...20 mA | – | M |
| InMax-30-BF | 30 Nm | 40/60/90/120/150 sec. | ~ 20 sec. | On-off, 3-pos | 2 × aux. switches (5°/85°) | InPro-TT-.. connector | M |
| InMax-50-BF | 50 Nm | 40/60/90/120/150 sec. | ~ 20 sec. | On-off, 3-pos | 2 × aux. switches (5°/85°) | InPro-TT-.. connector | M |
| InMax-60-BF | 60 Nm | 40/60/90/120/150 sec. | ~ 20 sec. | On-off, 3-pos | 2 × aux. switches (5°/85°) | InPro-TT-.. connector | M |
| Type | Torque | Running time 90° | Spring-return* | Control mode | Feedback | Features | Size |
|---|---|---|---|---|---|---|---|
| InMax-30- F3 | 24 Nm | 40/60/90/120/150 sec. | ~ 3 sec. | On-off | – | – | M |
| InMax-50- F3 | 40 Nm | 40/60/90/120/150 sec. | ~ 3 sec. | On-off | – | – | M |
| InMax-30-SF3 | 24 Nm | 40/60/90/120/150 sec. | ~ 3 sec. | On-off | 2 × aux. switches (5°/85°) | – | M |
| InMax-50-SF3 | 40 Nm | 40/60/90/120/150 sec. | ~ 3 sec. | On-off | 2 × aux. switches (5°/85°) | – | M |
| InMax-30-BF3 | 24 Nm | 40/60/90/120/150 sec. | ~ 3 sec. | On-off | 2 × aux. switches (5°/85°) | InPro-TT-.. connector | M |
| InMax-50-BF3 | 40 Nm | 40/60/90/120/150 sec. | ~ 3 sec. | On-off | 2 × aux. switches (5°/85°) | InPro-TT-.. connector | M |
*At low temperatures the spring-return time might vary. For further assistance please contact our sales team.
| Type | Description/Technical data |
| InSwitch | External, adaptable, on site adjustable auxiliary switch with 2 potential free contacts, adaptable to InMax-.. actuators |
| InBox-3P | Terminal box connectable to InMax-.. actuators with 1 cable for On-off or 3-pos operation |
| InBox-3P/SW | Terminal box connectable to InMax-.. actuators with 1 cable for On-off or 3-pos operation + 2 cable for external aux. switches type InSwitch |
| InBox-Y/S | Terminal box connectable to InMax-.. actuators with 2 cable, for modulating operation or 3-pos + integrated switches (HS) |
| InBox-Y/S/SW | Terminal box connectable to InMax-.. actuators with 2 cable, for modulating or 3-pos operation with feedback signal + 2 cable for external aux. switches |
| InBox-BF | Terminal box connectable to InMax-.. actuators with 1 cable, for all InMax-...-BF |
| InBox-BF/SW | Terminal box connectable to InMax-.. actuators with 1 cable, for all InMax-...-BF + 2 cable for external aux. switches type InSwitch |
| MKK-M | Mounting bracket for ..Box-terminal boxes for direct coupling to ..Max-.. actuators size M |
| HV-MU | Manual override, connectable to actuators size M |
| AR-16-xx | Squared reduction part from 16 × 16 mm to shafts with 14 mm (type AR-16-14), 12 mm (type AR-16-12) |
| InPro-TT-... | Safety temperature trigger for fire dampers, switching at 72°C, with 1 m cable, suitable only for InMax-...-BF actuators ! |
| EXC-DS1/VA | Safety temperature sensor for duct mounting, potential free contact, switching at 70°C...160°C (10°C steps) |
| DWB-M | Angle rotation limiter for mounting on actuator size M |
| Retrofit-Kit-M | Mechanical adaptation for mounting on ..Max actuators size M, required to replace a previous type NOT30..-F3, NOT50..-F3 or NOT50.. |
| ADM | Different adaptations for different valves available. Please don't hesitate to ask for technical solution |