order no.mic+25/DD/TC
2 x pnp 350 mm
measuring range30 - 350 mm
designcylindrical M30
operating modeproximity switch/reflective mode
reflective barrier
window mode
particularitiesDisplay
UL Listed
ultrasonic-specific
means of measurementecho propagation time measurement
transducer frequency320 kHz
blind zone30 mm
operating range250 mm
maximum range350 mm
resolution0.025 mm
reproducibility± 0.15 %
accuracy± 1 % (temperature drift internally compensated)
electrical data
operating voltage UB9 - 30 V d.c., reverse polarity protection
voltage ripple± 10 %
no-load current consumption≤ 80 mA
type of connection5-pin M12 initiator plug
outputs
output 1switching output
pnp: Imax = 200 mA (UB-2V)
NOC/NCC adjustable, short-circuit-proof
output 2switching output
pnp: Imax = 200 mA (UB-2V)
NOC/NCC adjustable, short-circuit-proof
switching hysteresis3 mm
switching frequency25 Hz
response time32 ms
delay prior to availability< 300 ms
inputs
input 1com input
synchronisation input
housing
materialbrass sleeve, nickel-plated, plastic parts, PBT, TPU
ultrasonic transducerpolyurethane foam, epoxy resin with glass contents
class of protection to EN 60529IP 67
operating temperature-25°C to +70°C
storage temperature-40°C to +85°C
weight150 g
further versionsstainless steel
cable connection (on request)
further versionsmic+25/DD/TC/E
technical features/characteristics
temperature compensationyes
controls2 push-buttons + LED display (TouchControl)
scope for settingsTeach-in and numeric configuration via TouchControl
LCA-2 with LinkControl
Synchronisationyes
multiplexyes
indicators3-digit LED display, 2 x three-colour LED
particularitiesDisplay
UL Listed