order no.crm+35/IU/TC/E
1 x analogue 4-20 mA + 0-10 V 600 mm
measuring range85 - 600 mm
designcylindrical M30
operating modeanalogue distance measurements
particularitieshigh chemical resistance
stainless steel version
display
ultrasonic-specific
means of measurementecho propagation time measurement
transducer frequency360 kHz
blind zone85 mm
operating range350 mm
maximum range600 mm
resolution0.069 mm to 0.17 mm, depending on the analogue window
reproducibility± 0.15 %
accuracy± 1 % (temperature drift internally compensated)
electrical data
operating voltage UB9 - 30 V d.c., reverse polarity protection
voltage ripple± 10 %
no-load current consumption≤ 80 mA
type of connection5-pin M12 initiator plug
outputs
output 1analogue output
current: 4-20 mA / voltage: 0-10 V (at UB ≥ 15 V), short-circuit-proof
switchable rising/falling
response time64 ms
delay prior to availability< 300 ms
inputs
input 1com input
synchronisation input
housing
materialstainless steel, plastic parts: PBT, TPU
ultrasonic transducercoated with PEEK film, PTFE O-ring
class of protection to EN 60529IP 67
operating temperature-25°C to +70°C
storage temperature-40°C to +85°C
weight150 g
further versionscable connection (on request)
technical features/characteristics
temperature compensationyes
controls2 push-buttons + LED display (TouchControl)
scope for settingsTeach-in and numeric configuration via TouchControl
LCA-2 with LinkControl
Synchronisationyes
multiplexyes
indicators3-digit LED display, 2 x three-colour LED
particularitieshigh chemical resistance
stainless steel version
display