Ball Float Type Level Switch HM-95

Type : Ball Float

Installation : Top Mounting

Switch Type : Micro Switch

Contact Rating : AC 250V 15A, DC 125V 0.5A

Wetted Part Material : SUS 316

Enclosure : Weather Proof

Pressure / Temperature : 10kg/cm2 /120deg.C

Process Connection Size / Material : JIS 125A 10K RF/ SUS 316

Head Material : Al. Cast + SS41

Output Signal : 1-DPDT

Measuring Length (Setting Point) : LP (in the rightdrawing) should be informed.

Conduit Connection : PF 1/2" (Adapter)

Medium : It should be informed.

Sp. Gr : It should be informed.

  • HM-90-2F-Ex
  • Liên hệ
  • 802
  • Thông tin sản phẩm
  • Bình luận

HM-95 Series is a Float Type Level Switch which detects liquid level by using of float and is mainly applied for high temperature and pressure vessel such as Boiler drum, Petrochemical Industry and Power plant, etc. It is used for the process performing alarm function when filling and discharging of the tank. Weather Proof and Ex-Proof version are available in accordance with requirement of site.

Characteristics

- Widely used to detect various liquid levels

- Strong structure and long life cycle

- Applicable to high temperature and pressure

- Easy installation 

- Applicable to explosion area (Ex-Proof version)

Operation Principle

When liquid level rises, the core connected to the float is also rising. The movement of core produces the contact output signal (SPDT or DPDT) by switching mechanism.

 

LOW ALARM

HIGH ALARM

 

 

 

Specification

 

 

 

 

Dimension of Housing as per Temperature

 

 

 

 

 

 

 

Dimension

 

Standard Version (HM-95)

High Temp. Version (HM-95H)

Ex-Proof Version (HM-95-Ex)

Standard Version (HM-95B)

High Temp. Version (HM-95BH)

Ex-Proof Version (HM-95B-Ex)

Actual Product may have a tolerance slightly.

 

 

 

 

 

Dimension

 

Standard Version (HM-95V)

High Temperature Version (HM-95VH)

Ex-Proof Version (HM-95V-Ex)

* Actual product may have a tolerance slightly.

 

 

 

 

 

 

Installation

 

Below recommendation should be considered when installation.

 

Product should be installed at the place far from inlet in order to avoid the malfunction.

Protection tube or external chamber should be applied if there is a flow or slopping of the medium in the tank.

Bracket should be installed with the product when the installation on the concrete as per above figure.

Inner diameter ("d") of tank nozzle should be larger than the outer diameter of float as per above figure.

 

 