Linear-Transducer LMRS27 341-20008 TR Electronic
Supply voltage
24 VDC, -20…+10 %
Current consumption no load
<= 250 mA
Measuring principle
magnetostrictive
Measuring length, standard
50…4000 mm, in steps
Resolution
0.01 mm
Linearity deviation
<= ± 0.015 % FS (min ± 50 µm)
Reproducibility
<= ± 0.005 % FS (min ± 10 µm)
Hysteresis
0.02 mm <= 1500 mm
0.1 mm > 1500 mm
Characteristics - Validity
using original TR Magnets
Temperature coefficient
< 8 µm/°C <= 500 mm
< 15 ppm/°C FS > 500 mm
FS:
Full-Scale
Straight line velocity
no restrictions
Mounting position
no restrictions
Rod end mounting
Option
Magnet
T4-M33
other on request
EtherNet/IP™ - Interface
EtherNet/IP™
IEC 61784-1 CP 2/2, IEC 61158
Physical Layer
Fast Ethernet, ISO/IEC 8802-3
Device profile
Encoder Device Profile 0x22
Transmission rate
Specific value
100 MBit/s
Parameter/Function, changeable
Resolution
Number of magnets
Preset parameter
Position averaging
Temperature parameter
Counting direction
Velocity parameter
Type of parametrization
programmable
Programming - Tool
Fieldbus-Device
TR-Soft: TRWinProg
Cycle time internal, <= 0.50 m
0.50 ms
Cycle time internal, <= 1.00 m
0.50 ms
Cycle time internal, <= 1.50 m
0.75 ms
Cycle time internal, <= 2.00 m
1.00 ms
Cycle time internal, <= 3.00 m
1.50 ms
Optional Magnets
Number of magnets
3, 30
Magnet - Minimum distance
80 mm
LMRS_27 Interface-Box EIP | |
---|---|
341-20008 |
|
MEASURING LENGTH | 0,00 MM |
ROD LENGTH | 0,00 MM |
RESOLUTION | 0,01 |