Loa thông báo E2S GNEXS1FDC024AB1A1R E2S GNExS1F Alarm Horn Sounder

0944911836 Ms. Duyên 0972835740 Ms. Hà 0385097045 Mr. Hiếu 0392468875 Ms. Anh 0707602728 Ms. Vân
Loa thông báo E2S GNEXS1FDC024AB1A1R  E2S GNExS1F Alarm Horn Sounder

Loa thông báo E2S GNEXS1FDC024AB1A1R E2S GNExS1F Alarm Horn Sounder

The GNExS1F is an IECEx and ATEX certified alarm horn sounder featuring a re-entrant flare horn. The robust GRP (glass reinforced polyester) enclosure is approved for Zone 1 & Zone 2 explosion proof signalling applications.
  • E2S GNEXS1FDC024AB1A1R
  • Liên hệ
  • 31
  • Thông tin sản phẩm
  • Bình luận

Loa thông báo E2S GNEXS1FDC024AB1A1R  E2S GNExS1F Alarm Horn Sounder

Description

Featuring 64 alarm tone sounds, each of the available 4 stage/channels can be remotely triggered. Class D amplification provides a high sound output at optimum an operating current. The threaded flameproof joint, multiple cable entries and duplicated, pluggable termination simplifies both installation and routine maintenance. SIL1 & SIL2 Route 2H compliant to IEC61508 (2010) as standard, with optional diagnostic module for Route 1H SIL2 compliance.

Specification

Maximum output: 115dB(A) @ 1 m +/- 3dB [106dB(A) @ 10ft/3m +/- 3dB]
Nominal output: 110dB(A) @ 1m +/- 3dB [101dB(A) @ 10ft/3m] +/- 3dB
No. of tones: 64 (UKOOA / PFEER compliant)
No. of stages: 4
Volume control: Full range
Effective range: 125m/410ft @ 1KHz
Voltages DC: 24Vdc (10-30Vdc), 48vdc (38-60Vdc)
Voltages AC: 230Vac (100-260Vac)
In-rush: 815mA within 4ms @ 24Vdc
Stage switching: DC units: positive or negative
AC units: common supply line
Safety Integrity Level: Product version A: SIL1 and SIL2 Route 2H
Product version S: SIL2 Route 1H with diagnostics SFF: >99%
See install manual for reliability & functional safety data
Ingress protection: EN60529: IP66
Enclosure material: UV stable GRP (glass reinforced polyester)
Enclosure colour: Natural Red
Enclosure finish: Natural – can be painted in alternative colours
Cable entries: 2 x M20x1.5mm
Stopping plug included
Stopping plugs: Brass, Nickel Plated or Stainless Steel
Terminals: 0.5 – 2.5mm² (20-14 AWG)
Pluggable & duplicated terminals
Line monitoring: Diode polarized for use in supervised circuits
Blocking diode for reverse polarity monitoring
Ground/Earth stud: M4
Line monitoring: Blocking diode included
EOL Min. 500 Ohm 2W, or 3k3 Ohm 0.5W resistor
or diode (DC versions) can be fitted
Enclosure volume: <2 litres
Installation temp: -50° to +70°C (-58°F to +158°F)
Storage temp: -50° to +70°C (-58°F to +158°F)
Relative humidity: 99%
MTBF DC: 93.92 years / 822,706 hours – MIL 217
MTBF AC: 46.66 years / 408,508 hours – MIL 217
Weight: DC: 3.00kg/6.6Ibs AC: 3.20kg/7.04Ibs

Part Codes

Part Code: Identifier: Description:
Product type: GNExS1 GNExS1 alarm horn sounder
Horn type: F Flare re-entrant horn
Voltage: DC024
DC048
AC230
10-30Vdc
38-60Vdc
100-260Vac
Cable entries:[e] A
B
C
D
E
F
G
2 x M20x1.5mm
2 × 1/2" NPT – adaptors
2 × 3/4" NPT – adaptors
2 x M25x1.5mm – adaptors
1 × 1/2" NPT – adaptor
1 × 3/4" NPT – adaptor
1 x M25x1.5mm – adaptor
Stopping plug/
adaptor material: [m]
B
N
S
Brass
Nickel plated brass
Stainless steel
Bracket material: [s] 1
3
5
A4 316 Stainless Steel
A4 316 St/St with Equip. Tag
A4 316 St/St with Equip. Tag and Duty Label
Product version: [v] A

S

T
IECEx, ATEX, Ex EAC, INMETRO
SIL1 & SIL2 Route 2H
IECEx, ATEX, Ex EAC, INMETRO
SIL2 Route 1H with diagnostics SFF: >99%
IECEx, ATEX, Ex EAC, INMETRO – Telephone/Relay initiate
Product option: [o] 1
Z
X
Y
K
V
R
Standard product
Custom alarm tone software – contact E2S
Custom configuration – contact E2S
Stage control Config. 4
Stage control Config. 5 (DC) and Config. 2 (AC)
Stage control Config. 6
Reverse polarity stage control (DC) Config. 7
Enclosure colour: [x] R
S
Red
Special – contact E2S for alternative enclosure colours
Accessories:
SP65-0001-A4
SP65-0003-A4
  Pole Mount Bracket Kit St/St A4 (316)
Sunshade – St/St A4 (316)
Alarm stage control:
Please review the installation manual and wiring schematics for remote stage control and EOL resistor monitoring configuration options:
Config. 1 [DC]: Factory default. Common negative, positive switching. Up to 4 Alarm Stages. EOL monitoring Alarm Stage 1 only
Config. 2 [DC]: User setting. Common positive, negative switching. Up to 4 Alarm Stages. EOL monitoring Alarm Stage 1 only
Config. 3 [DC]: User setting. Common negative, positive switching activation of Alarm Stages 1 & 2 with EOL on both stages. Reverse polarity monitoring
Config. 4 [DC]: Product option ‘Y’. Independent activation of Alarm Stages 1 & 2 with EOL on both stages. Forward polarity monitoring
Config. 5 [DC]: Product option ‘K’. Horn continuously powered. Voltage free activation of up to 3 alarm stages
Config. 6 [DC]: Product option ‘V’. Independent activation of up to 4 Alarm Stages with EOL on all stages. Forward polarity monitoring
Config. 7 [DC]: Product option ‘R’. Reverse polarity selection of Stage 1 and Stage 2
Config. 1 [AC]: Factory default. Up to 4 Alarm Stages. Stage 1 activated at power on. Stages 2, 3 and 4 via volt free contacts
Config. 2 [AC]: Product option ‘K’. Horn continuously powered. Voltage free activation of up to 3 alarm stages

 

 

Sản phẩm cùng loại