Bộ chỉnh nguồn Mini Power Regulator Para-ENT PS-025-I-FN , TS-025-I-FN

0944911836 Ms. Duyên 0972835740 Ms. Hà 0385097045 Mr. Hiếu 0392468875 Ms. Anh 0707602728 Ms. Vân
Bộ chỉnh nguồn Mini Power Regulator  Para-ENT PS-025-I-FN , TS-025-I-FN

Bộ chỉnh nguồn Mini Power Regulator Para-ENT PS-025-I-FN , TS-025-I-FN

  • Liên hệ
  • 1999
  • Thông tin sản phẩm
  • Bình luận

Product Description

 - The smallest digital power regulator :

  26mm width - Single phase / 115mm width – three phase

- Suitable for replacing SSR which has no protecting device. SCR module equipped in Mini is far more durable and reliable than TRIAC in SSR.

- Improved safety through alarming SCR failure which SSR can not detect

- Stable, Reliable and Convenient

Features

Comparison between Mini and SSR

Content Mini SSR Remark
Load failure alarm Basically installed Should attach additional C/T outside or load failure detector Mini has own C/T inside
Over current alarm Basically installed None Output current is more than 100% of its rated current
Over temperature alarm 60℃ Warning, 80℃ Alarm Mechanical contact  
Power module failure alarm Basically installed None  
Input signal Select one among 4~20mA / 0~10VDC / SSR SSR Select on ordering
Alarm point Basically 2points (Warning 1, Alarm 1) None  
Display One three color LED displaying operation status and alarm LED displaying operation status  
PCB Power 10~30VDC None

Stability, reliability and convenience

- When power module is failed, electric power to heater is not controlled at full power, which can cause a fire.

- Thus, to detect power module failure is very important to safety directly. Mini equipped with its own CT and CPU secures safety. This is different from SSR which can not detect power module failure.

- In case of SSR, additional device as CT or load failure detector should be attached to detect load failure. But Mini has its own CT, so no need to install any other device which can save labor cost and remove unnecessary wiring job. Eventually, it maximizes convenience.

- Control accuracy is enhanced with compensation algorithm.

 

- Long period of experience in digital power regulator allows Mini to satisfy stability and reliability.

Ordering Code

 

 

① NO. of phase PS : Mini single phase      TS : Mini three phase
② Rated current Single phase 010 : 10A / 025 : 25A / 040 : 40A
Three phase 025 : 25A / 040 : 40A / 055 : 55A / 070 : 70A
③ Input signal I : 4~20mA / V : 0~10VDC / S : SSR
④ Cooling fan Single phase NONE : Without cooling fan (Cooling fan can not be attached on 10A and 25A)
FN : With cooling fan (Only on 40A)
Three phase NONE : Without cooling fan
FN : With cooling fan (40A, 55A & 70A Cooling fan is basically installed)
 

 

 

 

 

Specification

Model Mini (Single phase) Mini (Three phase)
Rated voltage 50~500VAC 50~500VAC
Rated current 10A / 25A / 40A 25A / 40A / 55A/ 70A
Frequency 50/60Hz (Auto selectable) 50/60Hz (Auto selectable)
Minimum load 1A 1A
Output range Zero-Crossing 0~98% Zero-Crossing 0~98%
PCB power source 10~30VDC 10~30VDC
Input signal Select one among 4~20mA / 0~10VDC / SSR Select one among 4~20mA / 0~10VDC / SSR
Output NPN Open collector 2CH (Vc 〈 30V, Ic ≤ 50mA) NPN Open collector 2CH (Vc 〈 30V, Ic ≤ 50mA)
Control Method Zero-Crossing control with compensation algorithm Zero-Crossing control with compensation algorithm
Cooling 10A, 25A, 40A : Natural cooling /
40A Cooing fan (Option)
25A : Natural cooling (Cooling fan - Option) /
40A, 55A, 70A : Cooling fan installed
Alarm Over Current, Over Temperature of heatsink(60℃, 80℃),
Load Failure, SCR failure
Over Current, Over Temperature of heatsink(60℃, 80℃),
Load Failure, SCR failure, Unbalanced Load
Ambient Temp. 0 ~ 40℃ 0 ~ 40℃
Humidity 40% ~ 85% RH (No condensation) 40% ~ 85% RH (No condensation)
Display One three color LED One three color LED, Three single color LED’s
NET WT. 10A, 25A : 287g /
40A(Without fan) : 431g / 40A(With fan) : 454g
25A : 970g(Without fan) /
40A, 55A, 70A : 1.4Kgs (With fan)
Installation Bolt or DIN-rail Bolt