Model No. | BRC-G24T | BRC-G44T |
Kind | 4-point transmitter | |
Power source | Alkaline cell 4 pcs | |
Battery life : approx.9 hours under continuous use | ||
Power switch and automatic power-off function are provided(It will be off if no key input for 30sec.) | ||
Projecting element | Infra-red LED | |
Directional angle | Full angle 30° | |
Transmission distance | 10m | 20m |
Transmission point | 4 points | |
Transmission method | Transmitted by transmission key(1 to 4), Double key-in is also available by changeover switch | |
Transmission check | Electronic buzzer(Ringing during transmitting) | |
Case | ABS resin(Handling part : Polyester film) | |
Weight | Approx. 120g |
Specifications(Transmitter)
Model No. | BRC-G2BT | BRC-G4BT |
Kind | 12-point transmitter | |
Power source | Alkaline cell 4 pcs Battery life : approx.9 hours under continuous use Power switch and automatic power-off function are provided(It will be off if no key input for 30sec.) |
|
Projecting element | Infra-red LED | |
Directional angle | Full angle 30° | |
Transmission distance | 10m | 20m |
Transmission point | 12 points | |
Transmission method | Transmitted by transmission key(1 to 12), Double key-in is also available by changeover switch | |
Transmission check | LED(Lighting during transmitting) | |
Case | ABS resin(Handling part : Polyester film) | |
Weight | Approx. 200g |
Specifications(Receiver)
Model No. | BRC-G2AR | BRC-G2BR | BRC-H2AR | BRC-H2BR |
Kinds | 4 points | 12 points | 4 points | 12 points |
HEAD-ON | FRONT-ON | |||
Power source | 24VDC(±20%, ripple 10% or less) | |||
Reception element | Photo-diode | |||
Directional angle | 50°for vertical and 90°for horizontal(Full angle) | |||
Reception method | FSK modulation, output is effective when reverse code corresponds | |||
F number registration | Set by transmitter | |||
Output | Data output : 4 pcs(BRC-G2AR, BRC-H2AR), 12 pcs(BRC-G2BR, BRC-H2BR), strobe : 1 pcs, photo-coupler isolation, open-collector output(Max.35V, 50mA, residual voltage Max. 1.5V) Note) It executes only when registered F No. code would coincide receiving F No.code. |
|||
Connection | Cable with connector(2m long) | |||
Ambient illuminance | 10,000lx or less(Fluorescent lamp, mercury lamp) | |||
Ambient temperature | -10 degrees C to +50 degrees C | |||
Ambient humidity | 45 to 85%RH | |||
Protective structure | IP66(IEC standard) |
In case that, press any keys(1 to 4) after putting power source on.
Turn to the normal mode and it is possible to transmit.