Bộ điều khiển JOHNSON CONTROLS LP-KIT006-000C ,LP-FX16X01-511C , LP-FX16X01-000C, LP-FX16D01-000C

0944911836 Ms. Duyên 0972835740 Ms. Hà 0385097045 Mr. Hiếu 0392468875 Ms. Anh 0707602728 Ms. Vân
Bộ điều khiển JOHNSON CONTROLS  LP-KIT006-000C ,LP-FX16X01-511C ,  LP-FX16X01-000C, LP-FX16D01-000C

Bộ điều khiển JOHNSON CONTROLS LP-KIT006-000C ,LP-FX16X01-511C , LP-FX16X01-000C, LP-FX16D01-000C

The Facility Explorer Commercial Zoning Control Package is a complete, turnkey control system used to improve occupant comfort in a building (or section of a building) that is conditioned with a packaged Heating, Ventilating, and Air Conditioning (HVAC) air handling unit feeding several areas of dissimilar heating and cooling demands. The system consists of an FX16 Master Controller, integrated damper/controller/actuator assemblies, application software, and other ancillary control devices, such as sensors and switches, all working together in a coordinated control system.
  • LP-KIT006-000C
  • Liên hệ
  • 605
  • Thông tin sản phẩm
  • Bình luận

Table 8: FX16 Master Controller (One Required for Each Rooftop)
Part Number Description
Bộ điều khiển JOHNSON CONTROLS  LP-FX16X01-511C FX16 Master Controller with extended temperature rating, N2 communication card, and factory-installed FX Commercial Zoning application software
Bộ điều khiển JOHNSON CONTROLS LP-FX16X01-000C FX16 Master Controller with extended temperature rating, N2 communication card(application-less)
Bộ điều khiển JOHNSON CONTROLS LP-FX16D01-000C FX16 Master Controller with normal temperature rating, N2 communication card(application-less)

Part Number Description
ZOVSF-wwwxhhh Rectangular Zone Damper/Controller/Actuator Assembly, where www = width in inchesand hhh = height in inches (008x008 to 030x030). Includes factory-installed
LP-FXZAN13-0 Zone Controller/Actuator Assembly.
RZGddFDNO Round Zone Damper/Controller/Actuator Assembly, where dd = diameter in inches (6 to 18, in 2-inch increments). Includes factory-installed LP-FXZAN13-0 Zone Controller/Actuator Assembly.
LP-FXZAN13-0 Zone Controller/Actuator Assembly. Only needed if retrofitting to existing zone damper or if field mounting to the zone damper is preferred. 

Table 10: Zone Sensor (One Zone Sensor Required for Each Zone)
Part Number Description
LP-KIT006-005C Zone temperature sensor with push button for temporary occupancy and warm/cooladjustment dial. Includes wall mounting base and hardware. 

Table 11: Supply Duct Static Pressure Control Components (One Damper Assembly and One Sensor
Required for Each Rooftop)
Part Number Description
BOVSG-wwwxhhho Rectangular Bypass Damper/Actuator Assembly, where www = width in inches,hhh = height in inches, and o = options (none = no options, C = cover over actuator).Includes factory-installed M910XHGA non-spring return, proportional actuator.
RCGddEENC Round Bypass Damper/Actuator Assembly, where dd = diameter in inches (6 to 18 in.2-inch increments), NC = normally closed. Includes factory-installed M910xHGAnon-spring return, proportional actuator.
DPT2640-005D Supply duct static pressure sensor (0-5 in. Water Column [W.C.])

Table 12: Medium User Interface (One Optional for Each FX16)
Part Number Description
LP-DIS60P10-0C Local mount (<3 m [9.8 ft]) Medium User Interface. Includes panel mount hardware.
LP-KIT007-000C Interface cable for connection of local mount MUI to FX16
LP-DIS60P11-0C Remote mount (<300 m [984 ft]) Medium User Interface. Includes wall mount hardware. 

Table 13: Required Accessories
Part Number Description
Cảm biến nhiệt độ JOHNSON CONTROLS  TE-6313P-1 Outdoor air temperature sensor. Includes nickel element with 3-inch probe. One requiredfor each rooftop.
Cảm biến nhiệt độ JOHNSON CONTROLS TE-6311P-1 Duct probe temperature sensor. Includes nickel element with 8-inch probe. One requiredfor supply air temperature.
Table 14: Optional Accessories
Part Number Description
Mô đun mở rộng  JOHNSON CONTROLS LP-XT91D00-000C
Mô đun mở rộng  JOHNSON CONTROLS  -XP91D02-000C Extension/Expansion Modules. Needed to expand FX16’s I/O capability (if return airtemperature and return air humidity are required).
TE-6311P-1 Duct probe temperature sensor. Includes nickel element with 8-inch probe. One each usedfor mixed air and return air temperature.
HE-67N3-XXXXX Combination humidity and temperature (nickel element) sensor. Used for outside air andreturn air temperature and humidity.
CD-P00-00-0 Carbon dioxide sensor (duct mount)
Cảm biến chênh áp JOHNSON CONTROLS  P32AF-1C or -2C Differential pressure switch. Used for filter status. P32AF-1C includes L bracket. P32AF-2C includes U bracket.H708 Current sensing relay. Optionally used for fan status.
LP-FXTEXP-0 FX Tools Express. Includes FX-Builder Express and FX CommPro N2. Used for software configuration and commissioning.
LP-KIT100-000C FX Programming Key. Used for downloading application to FX16

 

Sản phẩm cùng loại