Cảm biến đo độ ẩm nhiệt độ Senseca HD2717T… Series – Interchangeable Probe Active Transmitters

0944911836 Ms. Duyên 0972835740 Ms. Hà 0385097045 Mr. Hiếu 0392468875 Ms. Anh 0707602728 Ms. Vân
Cảm biến đo độ ẩm nhiệt độ Senseca HD2717T… Series – Interchangeable Probe Active Transmitters

Cảm biến đo độ ẩm nhiệt độ Senseca HD2717T… Series – Interchangeable Probe Active Transmitters

The instruments of the HD2717T... series are transmitters, indicators, and ON/OFF regulators with data logging functions for the measurement of temperature and humidity.

The instruments of the HD2717T… series are transmitters, indicators, and ON/OFF regulators with data logging functions, they measure temperature and humidity.

The main feature of these instruments is their interchangeable probe. The probe can be replaced by the user without process interruption. Thus, the probe can be calibrated or repaired at a later time.

The instrument is available in different versions: with horizontal probe (S.TO), vertical probe (S.TV) or with remote probe (S.TC), having the probe connected to the electronics by means of a cable of various lengths.

The S.TO and S.TV probes are made of stainless steel AISI304, the S.TC probes can be of stainless steel AISI304 or plastic material.

The probe is factory calibrated and ready to use, it is provided with a SICRAM2 module which stores the calibration data of the probe, allowing the interchangeability of the probes.

The instruments measure:

Temperature in Celsius or Fahrenheit temperature scale

Relative humidity

and calculate:

Absolute humidity

Mixing Ratio

Dew point

All models have both current and voltage outputs.

Some models are fitted with two control relays and one alarm relay, configurable by the user.

All models are fitted with a multistandard RS232/RS485 serial port and an auxiliary RS232C standard serial output. The RS485 serial output allows the management of more than one device in a network.

The data logger function allows to store the measures with a selectable storage interval.

Probes:

S.TV – Vertical probe L= 130mm, AISI 304

The material of the S.TC…probes can be chosen between stainless steel AISI304 or plastic material. (recognized by the letter P in the code)

S.TC1.2 and S.TC1.2P – Probe L=135mm with cable 2m

S.TC1.5 and S.TC1.5P – Probe L=135mm with cable 5m

S.TC1.10 and S.TC1.10P – Probe L=135mm with cable 10m

S.TC2.2 and S.TC2.2P – Probe L=335mm with cable 2m

S.TC2.5 and S.TC2.5P – Probe L=335mm with cable 5m

S.TC2.10 and S.TC2.10P – Probe L=335mm with cable 10m

Probes with cable for measurements in pipelines: S.TC2.480.2 and S.481.2

S.TO1 – horizontal probe L= 135mm

S.TO2 – horizontal probe L= 335mm
  • HD2717T… Series
  • Liên hệ
  • 95
  • Thông tin sản phẩm
  • Bình luận

Delta Ohm  Senseca  HD208.1NTC    Temperature and relative humidity mini-data logger. Combined external probe with cable, sensor NTC.
Delta Ohm  Senseca  HD208.1NTV    Temperature and relative humidity mini-data logger. Fixed probe.
Delta Ohm  Senseca  HD208.N    Temperature mini-data logger. Internal NTC sensor.
Delta Ohm  Senseca  HD208.NTC    Temperature mini-data logger. External probe with cable, sensor NTC. With LCD
Delta Ohm  Senseca  HD208.NTV    Temperature mini-data logger. NTC fixed probe.
Delta Ohm  Senseca  HD208L.1NTC    Temperature and relative humidity mini-data logger. Combined external probe with cable, sensor NTC. With LCD
Delta Ohm  Senseca  HD208L.1NTV    Temperature and relative humidity mini-data logger. Fixed probe. With LCD.
Delta Ohm  Senseca  HD208L.N    Temperature mini-data logger. Internal NTC sensor. With LCD.
Delta Ohm  Senseca  HD208L.NTC    Temperature mini-data logger. External probe with cable, sensor NTC.
Delta Ohm  Senseca  HD208L.NTV    HD208 series temperature data logger. NTC fixed probe. With LCD.
Delta Ohm  Senseca  HD2110RS    Connecting cable with M12 connector on instrument side and with 9 poles SubD female connector for RS232C on PC side.
Delta Ohm  Senseca  HD2717T.00    Transmitter, data logger for temperature and humidity. Model without  display and without  relay, power supply 90…240 Vac
Delta Ohm  Senseca  HD2717T.0/24    Transmitter, data logger for temperature and humidity. Model without  display and without  relay, power supply 24Vac/dc
Delta Ohm  Senseca  HD2717T.0R    Transmitter, ON/OFF regulator, data logger for temperature and humidity. Without LCD, with 2 working relays and 1 alarm relay , power supply 90…240 Vac
Delta Ohm  Senseca  HD2717T.0R/24    Transmitter, ON/OFF regulator, data logger for temperature and humidity. Without LCD, with 2 working relays and 1 alarm relay, power supply 24Vac/dc
Delta Ohm  Senseca  HD2717T.D0    Transmitter, indicator, data logger for temperature and humidity. Model with custom display, without relay, power supply 90…240 Vac
Delta Ohm  Senseca  HD2717T.D0/24    Transmitter, indicator, data logger for temperature and humidity. Model with custom display, without relay, power supply 24Vac/dc
Delta Ohm  Senseca  HD2717T.DR    Transmitter, indicator, ON/OFF regulator, data logger for temperature and humidity. With LCD, 2 work relays and 1 alarm relay, power supply 90…240 Vac
Delta Ohm  Senseca  HD2717T.DR/24    Transmitter, indicator, ON/OFF regulator, data logger for temperature and humidity. With LCD, 2 work relays and 1 alarm relay, power supply 24Vac/dc
Delta Ohm  Senseca  HD2717TO.00    Transmitter, data logger for temperature and humidity. Model without display and without relay, power supply 90…240 Vac
Delta Ohm  Senseca  HD2717TO.00/24    Transmitter, data logger for temperature and humidity. Model without display and without relay, power supply 24Vac/dc
Delta Ohm  Senseca  HD2717TO.0R    Transmitter, ON/OFF regulator, data logger for temperature and humidity. Without LCD, with 2 working relays and 1 alarm relay, power supply 90…240 Vac
Delta Ohm  Senseca  HD2717TO.0R/24    Transmitter, ON/OFF regulator, data logger for temperature and humidity. Without LCD, with 2 working relays and 1 alarm relay, power supply 24Vac/dc
Delta Ohm  Senseca  HD2717TO.D0    Transmitter, indicator, data logger for temperature and humidity. Model with custom display, without relay, power supply 90…240 Vac
Delta Ohm  Senseca  HD2717TO.D0/24    Transmitter, indicator, data logger for temperature and humidity. Model with custom display, without relay, power supply 24Vac/dc
Delta Ohm  Senseca  HD2717TO.DR    Transmitter, indicator, ON/OFF regulator, data logger for temperature and humidity. With LCD, 2 work relays and 1 alarm relay, power supply  90…240 Vac
Delta Ohm  Senseca  HD2717TO.DR/24    Transmitter, indicator, ON/OFF regulator, data logger for temperature and humidity. With LCD, 2 work relays and 1 alarm relay, power supply 24Vac/dc

Sản phẩm cùng loại