Cảm biến tải trọng part No: 00457277 PD 2125 Erhardt+Leimer load cell flange mounted
Accuracy class | 0,5 |
Nominal characteristic (Sensitivity) | 1 m V/V |
Combined error | < 0.5% |
Characteristic value tolerance | 0.2% |
Measuring principle | Full bridge strain gauge |
Nominal resistance of the bridge strain gauge | 700 Ohm |
Bridge supply voltage, nominal value | 10 V |
Bridge supply voltage, max. permissible value | 14 V |
Mechanical stop | 1.8 to 2.4 FN dep. on type |
Operating load | 1.8 to 2.4 FN |
Limit load | 20xFN |
Nominal measuring travel | 0.1 to 0.2 mm depending on type |
Nominal temperature range | -10 °C to +60 °C |
Operating temperature range | -10 °C to +90 °C |
Temperature coefficient | ±0.3% / 10 K (characteristic value) ± 0.3% / 10 K (zero signal) |
Protection class | IP 50 |
Max. permissible axial transverse force | 1xFN |
Weight | 2.3 kg (d1 = 17 mm), 3.6 kg (d1 = 25 mm), 8.5 kg (d1 = 35 mm) |
Erhardt+Leimer 00489201-PD 2125: KBT0783 load cell PD 2125 flange mounted, as per drawing M 057050, excluding bearings and circlips, shaft dia. 25 mm, open one side, measuring range 0.75 kN, protection class IP 54-00489201
Erhardt+Leimer 00457277-PD 2125: PD 2125 load cell flange mounted, as per drawing M 057050, excluding bearings and circlips, shaft dia. 25 mm, open one side, measuring range 0.15 kN, protection class IP 50-00457277
Erhardt+Leimer 00457278-PD 2125: PD 2125 load cell flange mounted, as per drawing M 057050, excluding bearings and circlips, shaft dia. 25 mm, open one side, measuring range 0.3 kN, protection class IP 50-00457278
Erhardt+Leimer 00457279-PD 2125: PD 2125 load cell flange mounted, as per drawing M 057050, excluding bearings and circlips, shaft dia. 25 mm, open one side, measuring range 0.75 kN, protection class IP 50-00457279
Erhardt+Leimer 00457281-PD 2125: PD 2125 load cell flange mounted, as per drawing M 057050, excluding bearings and circlips, shaft dia. 25 mm, open one side, measuring range 1.5 kN, protection class IP 50-00457281
Erhardt+Leimer 00394247-PDV: PDV tension measuring System consisting of: 2x PD 2125 Load Cell 0,75kN 2x Cable for Load Cell 10m 1x Accessories kit 1 for Load Cell 1x Accessories kit 3 for Load Cell 1x DC 6211 Web tension controller 1x SZ 2040 Terminal box 1x DP 2010 Pneumatic controller 1x CN 4007 Power supply 31m Pneumatic hose plastic 15m Cable from DC 6211 -> SZ 2040 1m Cable from SZ 2040 -> DP 2010 15m Cable from CN 4007 -> SZ 2040 / DC 6211 According to connection diagram: BLO-DC_6211-001 SPM-SZ_2040-009 SPM-DC_6211-001 STR-CN_4007-001-00394247
web tension monitors Erhardt+Leimer PD 21 + DC 6210-00515674: Web tension monitors consisting of: 2 pc. PD 2125 load cell flange mounted, as per drawing M 057050, excluding bearings and circlips, shaft dia. 25 mm, open one side, measuring range 0.3 kN, protection class IP 50 2 pc. PDV 0200-60 cable screened 4x A 0.75 10 mts with 1 socket, IP 50 1 pc. DC 6210 digital web tension controller, front panel mounting, 100mmx100mm as per dimension sheet 158357, colour touch display, amplifier for 2 load cells, integrated power unit for el. brakes 24V/4A, operating voltage 24V DC-00515674
web tension monitors Erhardt+Leimer PD 21 + DC 6210-00516439 Erhardt+Leimer : Web tension monitors consisting of: 2 pc. PD 2125 load cell flange mounted, as per drawing M 057050, excluding bearings and circlips, shaft dia. 25 mm, open one side, measuring range 0.15 kN, protection class IP 50 2 pc. PDV 0200-60 cable screened 4x A 0.75 20 mts with 1 socket, IP 50 1 pc. DC 6210 digital web tension controller, front panel mounting, 100mmx100mm as per dimension sheet 158357, colour touch display, amplifier for 2 load cells, integrated power unit for el. brakes 24V/4A, operating voltage 24V DC-00516439
web tension monitors Erhardt+Leimer PD 21 + DC 6210-00516757 Erhardt+Leimer : Web tension monitors consisting of: 2 pc. PD 2125 load cell flange mounted, as per drawing M 057050, excluding bearings and circlips, shaft dia. 25 mm, open one side, measuring range 1.5 kN, protection class IP 50 2 pc. PDV 0200-57 cable screened 4x A0.75 20 m with 1 coupling, IP 50 1 pc. DC 6210 digital web tension controller, front panel mounting, 100mmx100mm as per dimension sheet 158357, colour touch display, amplifier for 2 load cells, integrated power unit for el. brakes 24V/4A, operating voltage 24V DC-00516757 Erhardt+Leimer
web tension monitors Erhardt+Leimer PD 21 + PA 6200-00851490 Erhardt+Leimer : Web tension monitors consisting of: 2 pc. 457277 PD 2125 load cell flange mounted, as per drawing M 057050, excluding bearings and circlips, shaft dia. 25 mm, open one side, measuring range 0,15 kN, protection class IP 50 2 pc. #511666 PDV 0200-57 cable screened 4x A 0.75 10 mts with 1 coupling, IP 50 1 pc. #489218 PA 6200 web tension amplifier and display, front panel mounting, amplifier for 2 separate load cells, LCD colour touch display, 2x output signal 0..10V and 0/4..20mA, web tension monitoring with 3 dig. alarm outputs, Ethernet interface for setup and service, operating voltage 24V DC, 100mmx100mmx50mm as per dimension sheet 158566-00851490 Erhardt+Leimer
web tension monitors PD 21-00855252 Erhardt+Leimer : Web tension monitors consisting of: 1 pc. 457277 PD 2125 load cell flange mounted, as per drawing M 057050, excluding bearings and circlips, shaft dia. 25 mm, open one side, measuring range 0,15 kN, protection class IP 50 1 pc. #504024 PDV 0200-57 cable screened 4x A 0.75 5 mts long with 1 coupling, IP 50-00855252
web tension monitors PD 21-00855260 Erhardt+Leimer : Web tension monitors consisting of: 1 pc. PD 2125 load cell flange mounted, as per drawing M 057050, excluding bearings and circlips, shaft dia. 25 mm, open one side, measuring range 0.3 kN, protection class IP 50 1 pc. PDV 0200-57 cable screened 4x A0.75, 15 m long, with 1 coupling, IP 50-00855260