Đèn tín hiệu Beacon MEDC SM87LED hãng MEDC SM87PBLSD1BNNNR MEDC SM87PBLSD1B1RNNNB MEDC SM87PBLAD1B1RNNNY
Certification | ATEX, IECEx, TR CU, Inmetro, |
Flameproof | ATEX Ex II 2GD, Exd(e) IIC T6 |
Area Classification | Zone 1 and Zone 2 use. |
Certified Ambient Temperature | -20°C to +55°C |
Ingress Protection | IP66 & 67 |
Material | Stainless Steel or Alloy |
Entries | Up to 4 x 20mm or 25mm |
Weight | Alloy: 2kg (approx.) Stainless Steel: 3.8kg (approx.) |
Options | Body & lens colour, lens guard, tel & relay initiate, EOL resistor, terminal chamber, voltages 24-48V d.c.& 110-254V a.c. |
SM87PBLSD1BNNNR
Manual Call Point SM87PBLSD1BNNNR. Pushbutton Latching Call Point, IP66 & IP67, Material: Stainless Steel, Certification: ATEX approved, Ex II 2 GD, Ex d IIC T5/T6 Gb, Ex tb IIIC T85°C/T100°C Db, Cable Entries: 1 x M20 Bottom, Duty Label: None, Tag Label: None, Features: None, Finish: Red.
SM87PBLSD1B1RNNNB
Abandon Platform Push Button SM87PBLSD1B1RNNNB. Pushbutton Latching Call Point, IP66 & IP67, Material: Stainless Steel, Certification: ATEX approved, Ex II 2 GD, Ex d IIC T5/T6 Gb, Ex tb IIIC T85°C/T100°C Db, Cable
Entries: 1 x M20 Bottom, 1 x M20 Right Hand Side, Duty Label: None, Tag Label: None, Features:None, Finish: Blue.
SM87PBLAD1B1RNNNY
Emergency Push Button SM87PBLAD1B1RNNNY. Pushbutton Latching Call Point, IP66 & IP67, Material: Marine Grade Alloy, Certification: ATEX approved, Ex II 2 GD, Ex d IIC T5/T6 Gb, Ex tb IIIC T85°C/T100°C Db, Cable
Entries: 1 x M20 Bottom, 1 x M20 Right Hand Side, Duty Label: None, Tag Label: None, Features: None, Finish: Yellow.
No |
Manuf |
Item |
Description |
Qty |
1 |
MEDC |
DB3B + XB11 Sounder Beacon Combination Unit Replaced for: DB3 + XB11 (obsolete)z |
DB3BDGD048N1BNR. Sounder, IP66 & IP67, GRP Ex Chamber, Thermoplastic Flare, Certification: ATEX Certified, Ex d, Ex Atmosphere: Ex II 2 GD, IIC T4/T5/T6 Gb, Ex tb IIIC T135°C/T100°C/T85°C Db, Voltage: 12-48VDC, Labels: None, Cable Entries: 1 x M20, Options: None, Finish: Natural Red. DB3B + XB11 Sounder Beacon Combination Unit comprises of XB11B02406RYDNNNR. Xenon Beacon (5 Joule), IP66 & IP67, Material: GRP, Certification: ATEX approved, Ex II 2 GD, Ex d IIB T4/T5/T6 Gb, Ex tb IIIC T75°C/T90°C/T105°C Db, 2 x M20 Entries, Voltage: 24VDC, Flash Rate: 60FPM, Lens Colour: Red, Lens Guard: Yes, Fixing: Direct Mounting Without Backstrap, Earth Continuity: None (Select this option for AU version), Labels: None, Options: None, Finish: Red. Units are wire inter-connection mounted on a two way stainless steel backplate painted with red finish. |
1 |
2 |
MEDC |
BGEB4B6B25DSN7R Manual Fire Alarm Call Point |
BGEB4B6B25DSN7R. Breakglass Call Point, IP66 & IP67, Material: GRP, Certification: ATEX approved Ex II 2G, EExed IIC T6 (T4 if resistors fitted), SIL2 approval, Cable Entries: 2 x M20 Bottom, Glass Label (2): BREAK GLASS PRESS HERE, Tag Label: Required Please specify details with order), Switches: Single Changeover (VDC), Features: None, Terminals: 7 x 2.5mm2, Finish: Red. |
2 |
3 |
MEDC |
SM87PBLSD1BNNNR Manual Call Point |
SM87PBLSD1BNNNR. Pushbutton Latching Call Point, IP66 & IP67, Material: Stainless Steel, Certification: ATEX approved, Ex II 2 GD, Ex d IIC T5/T6 Gb, Ex tb IIIC T85°C/T100°C Db, Cable Entries: 1 x M20 Bottom, Duty Label: None, Tag Label: None, Features: None, Finish: Red. |
2 |
4 |
MEDC |
SM87PBLSD1B1RNNNB Abandon Platform Push Button |
SM87PBLSD1B1RNNNB. Pushbutton Latching Call Point, IP66 & IP67, Material: Stainless Steel, Certification: ATEX approved, Ex II 2 GD, Ex d IIC T5/T6 Gb, Ex tb IIIC T85°C/T100°C Db, Cable Entries: 1 x M20 Bottom, 1 x M20 Right Hand Side, Duty Label: None, Tag Label: None, Features: None, Finish: Blue. |
1 |
5 |
MEDC |
SM87PBLAD1B1RNNNY |
SM87PBLAD1B1RNNNY. Pushbutton Latching Call Point, IP66 & IP67, Material: Marine Grade Alloy, Certification: ATEX approved, Ex II 2 GD, Ex d IIC T5/T6 Gb, Ex tb IIIC T85°C/T100°C Db, Cable Entries: 1 x M20 Bottom, 1 x M20 Right Hand Side, Duty Label: None, Tag Label: None, Features: None, Finish: Yellow. |
1 |
6 |
MEDC |
XB4BB8D1B06ANRN0R Indoor Pre-Discharge Warning Beacon |
XB4BB8D1B06ANRN0R. Xenon Beacon (21 Joule), IP66 & IP67, Certification: ATEX approved, Ex II 2 GD, Ex d IIC T4/T5/T6 Gb, Ex tb IIIC T85°C/T100°C/T135°C Db, Voltage: 24VDC, Termination: 8 x 6mm2, Cable Entries: 1 x M20, Flash Rate: 60FPM, Initiate Option: None, Lens Guard: None, Lens Colour: Red, Labels: None, Material: Stainless Steel, Finish: Red. |
1 |
7 |
MEDC |
SM87LED 24VDC MAIN PCB (RED OR AMBER LED'S), Replacing Board For Outdoor Warning Beacon |
SM87LED 24VDC MAIN PCB (RED OR AMBER LED'S), PX99901003 |
10 |
8 |
MEDC |
DB1HPBS024A1A3NNNR Indoor Pre-Discharge Warning Sounder |
DB1HPBS024A1A3NNNR. 27 Tone Sounder, up to 110+/-3dB, IP66, Material: Stainless Steel, Certification: ATEX approved, Ex II 2G, Ex d IIB T5 Gb, Voltage: 24VDC, Cable Entries: 1 x M20 Left Hand Side, 1 x M20 Bottom, Duty Label: None, Tag Label: None, Features: None, Finish: Red. |
1 |