Hệ thống cảnh báo khí gas Multi-Channel Gas Warning System GW 399 ADOS

0944911836 Ms. Duyên 0972835740 Ms. Hà 0385097045 Mr. Hiếu 0392468875 Ms. Anh 0707602728 Ms. Vân
Hệ thống cảnh báo khí gas Multi-Channel Gas Warning System GW 399 ADOS

Hệ thống cảnh báo khí gas Multi-Channel Gas Warning System GW 399 ADOS

Application

The multi-channel gas warning system GW 399 continuously monitors the ambient air and provides an early warning of hazardous, explosive and non-combustible gases and vapours.

Features

Use of various types of measurement sensor

Direct warning status recognition, via different colors of the LC-Display background illumination

Menu-aided operation, via 2 keys

Three alarm thresholds individually adjustable from 5-100% of test range

Three floating alarm outputs for driving additional warning and control systems

Floating relay contacts

Serial output, RS 232 or RS 485

4-20 mA current output

Different housings are available e. g. 19" rack,

panel mounting, wall-mounted housing

Up to 10 units per rack

1 control unit configurable as master, for supervision of central alarms and communication control systems

High degree of reliability

Low current consumption

Possibility of uninterruptible power supply

Fields of Application

Monitoring of heating systems

Garages and tunnels

Liquid gas rooms

Laboratories

Cold storage houses and air conditioning plants

Plastic processing plants

Chemical industries

Paint manufacturing plants

Concentration measurement of O2

and many more
  • GW 399 ADOS
  • Liên hệ
  • 837
  • Thông tin sản phẩm
  • Bình luận

Measurable gases

Gas Formula
Acetylen C2H2
Ether C4H10O
Alcohol e.g. C2H6O
Ammonia NH3
Petrol  
Butane C4H10
Chloroform CHCl3
Hydrogene chloride HCl
Helium He
Carbon dioxide CO2
Carbon monoxide CO
Methane (natural gas) CH4
Neon Ne
Propane C3H8
Oxygen O2
Carbon tetrachloride CCl4
Toluene C7H8
Hydrogen H2
Xylene C8H10

Accessories

Signal horn, warning light, warning banner, ventilation control, test meters, plotter.
Additional accessories are available, depending on the system ordered.

Technical Data

Details as for control unit
Sensors: Semiconductor sensor
Heat reaction sensor
Thermal conductivity sensor
Chemical sensor
Infrared sensor
Sensors input: 1 two-wire sensor (e. g. TOX 592) or 1 three-wire sensor (e.g. GTR 196)
Sensor supply: 20 V DC / 200 mA
Ranges: Adaptable by software
Accuracy: < 2 %, f.s.d.
Ambient temperature: -10 °C to +40 °C
Temperature effects: < 2 % for a ±20 °C change
Installation: Panel mounting or wall-mounting
Output signals: Current output 4-20 mA
RS 232 or RS 485 interface
3 Alarm relays
1 Fault relay
Relay rating: 230 V, 450 VA
other voltages on request
Voltage supply: 230 V, 50 Hz
Options: 115 V, 60 Hz  |  24 V DC  |  12 V DC
Power consumption: 8 VA