The STExS1F is a UL, cUL, IECEx and ATEX certified alarm horn sounder featuring a re-entrant flare horn. The robust 316L stainless steel enclosure is approved for Zone 1, 2, 21 & 22 explosion proof signalling applications.
  • E2S STEXS1RAC230DS2A1R
  • Liên hệ
  • 36
  • Thông tin sản phẩm
  • Bình luận

Loa thông báo E2S STEXS1RAC230DS2A1R STExS1F Alarm Horn Sounder E2S  STEXS1RAC230DS2A1C. E2S STExL2FV100AS2A1R, E2S STExC1X05RDC024CS4A1R/R

 

Description

Featuring 64 alarm tone sounds, each of the available 4 stage/channels can be remotely triggered. Class D amplification provides a high sound output at optimum operating current. The threaded flameproof joint, multiple cable entries and duplicated, pluggable termination simplifies both installation and routine maintenance. SIL1 & SIL2 Route 2H compliant to IEC61508 (2010) as standard, with optional diagnostic module for Route 1H SIL2 compliance. DNV type approved for exposed locations.

Part Codes

Part Code: Identifier: Description:
Product type: STExS1 STExS1 alarm horn sounder
Horn type: F Flare re-entrant horn
Voltage: DC024
AC230
11.5-54Vdc
100-240Vac
Cable entries:[e] A
B
C
D
E
F
G
3 x M20x1.5mm
2 × 1/2" NPT – adaptors
2 × 3/4" NPT – adaptors
2 x M25x1.5mm – adaptors
1 × 1/2" NPT – adaptor
1 × 3/4" NPT – adaptor
1 x M25x1.5mm – adaptor
Stopping plug/
adaptor material: [m]
S Stainless steel
Bracket material: [s] 1
3
A4 316 Stainless Steel
A4 316 St/St with Equip. Tag
Product version: [v] A

S

T
UL, cUL, ULC, IECEx, ATEX, DNV, Ex EAC
INMETRO SIL1 & SIL2 Route 2H
UL, cUL, ULC, IECEx, ATEX, Ex EAC, INMETRO
SIL2 Route 1H with diagnostics SFF: >99%
IECEx, ATEX, Ex EAC, INMETRO
Telephone/Relay initiate
Product option: [o] 1
Z
X
Y
K
V
Standard product
Custom alarm tone software – contact E2S
Custom configuration – contact E2S
Stage control Config. 4
Stage control Config. 5 (DC) and Config. 2 (AC)
Stage control Config. 6
Enclosure colour: [x] R
S
Red
Special – contact E2S for alternative enclosure colours
Accessories:
SP65-0001-A4
SP65-0003-A4
  Pole Mount Bracket Kit St/St A4 (316)
Sunshade – St/St A4 (316)
Alarm stage control:
Please review the installation manual and wiring schematics for remote stage control and EOL resistor monitoring configuration options:
Config. 1 [DC]: Factory default. Common negative, positive switching. Up to 4 Alarm Stages. EOL monitoring Alarm Stage 1 only
Config. 2 [DC]: User setting. Common positive, negative switching. Up to 4 Alarm Stages. EOL monitoring Alarm Stage 1 only
Config. 3 [DC]: User setting. Common negative, positive switching activation of Alarm Stages 1 & 2 with EOL on both stages. Reverse polarity monitoring
Config. 4 [DC]: Product option ‘Y’. Independent activation of Alarm Stages 1 & 2 with EOL on both stages. Forward polarity monitoring
Config. 5 [DC]: Product option ‘K’. Horn continuously powered. Voltage free activation of up to 3 alarm stages
Config. 6 [DC]: Product option ‘V’. Independent activation of up to 4 Alarm Stages with EOL on all stages. Forward polarity monitoring
Config. 1 [AC]: Factory default. Up to 4 Alarm Stages. Stage 1 activated at power on. Stages 2, 3 and 4 via volt free contacts
Config. 2 [AC]: Product option ‘K’. Horn continuously powered. Voltage free activation of up to 3 alarm stages
Sản phẩm cùng loại