Máy đo chất lượng nguồn điện Accura 3700 High Accuracy Digital Power Quality Meter Rootech

0944911836 Ms. Duyên 0972835740 Ms. Hà 0385097045 Mr. Hiếu 0392468875 Ms. Anh 0707602728 Ms. Vân
Máy đo chất lượng nguồn điện Accura 3700 High Accuracy Digital Power Quality Meter Rootech

Máy đo chất lượng nguồn điện Accura 3700 High Accuracy Digital Power Quality Meter Rootech

Overview

Gapless Measurements of Voltage and Current:

Max/Min/Avg Values Available at Aggregation Intervals

A Variety of Power Quality Data Available,including Voltage Dip(Sag)/Swell

Accurate Measurements of Voltage, Current, Active Power, and Active Energy

Power Quality Assessment with PQ Curve Data:

SEMI F47–0706, IEC 61000–4–11/34 Class 3, ITIC

IO Modules: Recording Events on Digital and Analog Inputs

Safety and Reliability approved by CE/UL Certifications

Improved Reliability and Maintenance with the Detachable POWER Module
  • Accura 3700 Rootech
  • Liên hệ
  • 2323
  • Thông tin sản phẩm
  • Bình luận
Voltage Input
Port name V1, V2, V3, VN
Connector type Terminal block1
Wire specification 1 – 2.5 mm2 (18 – 14 AWG), copper or aluminum
Wire temp rating Above 70 ˚C
Measurement catagory III
Withstand voltage AC 2,000 V RMS, 60 Hz for 1 minute
Impedance 10 MΩ/Phase
Burden 0.01 VA/Phase @ 220 V
Wiring method 3P4W, 3P3W, 1P3W, 1P2W
Current Input
Port name 1S, 2S, 3S ports on the power supply side, 1L, 2L, 3L ports on the load side (internal busbar)
Connector type Terminal block2
Wire specification 2.1 – 6.0 mm2 (14 – 10 AWG), copper or aluminum
Wire temp rating Above 70 ˚C
Rating Input 5 A nominal/10 A full scale 3~ continuous, per UL61010, 100A for 1 second (thermal)
Burden 0.01 VA/Phase @10 A
Basic Measurement
Frequency measurement Measuring range 42 – 69 Hz (50/60 Hz)
Basic measurement Measurement cycle(gapless) 0.2sec (12 cycles @60Hz, 10 cycles @50Hz)

Voltage

Sampling 512 samples/cycle

Measuring range(accuracy guaranteed)

60 – 520 V Line–to–line
35 – 300 V Line–to–neutral
Accuracy ±0.2 % Reading
Minimum measured value 5 V Line–to–neutral(based on the secondary voltage of the PT when external PTs are connected)

Residual voltage

Measuring method Calculation of the sum of sampled three–phase line–to–neutral voltages
Measurement data RMS, Fundamental
Accuracy / Operating range ±0.2% Un3 / Up to 300 V Line-to-neutral

Current

Sampling 256 samples/cycle
Measuring range(accuracy guaranteed) 1 % In – 200 % In4
Accuracy ±0.2% Reading
Minimum measured value 0.1 % In

Residual current

Measuring method Calculation of the sum of sampled three–phase currents
Measurement data RMS, Fundamental
Accuracy / Operating range ±0.2% In / Up to 200 % In of phase current

Energy

Active Received, Delivered, Net, Sum(total) energy
Reactive Energy in quadrant 1, 2, 3 and 4
Apparent

Demand

Current, Apparent power5, Active power Demand, Peak demand, Predicted demand6
Demand time setup Demand time = Demand sub–interval * the number of demand sub–intervals
Display

LCD

Type 5.0" Color TFT LCD
Resolution 800 x 480 pixel
Additional features LED backlight & touch panel
External Communication with the Host System

Ethernet communication

Protocol Modbus TCP Protocol
Port 2 ports, Ethernet switching7
Connector type RJ45 connector
Communication cable Ethernet cable Cat 5e FTP, STP, SFTP8
Cable length Up to 100 m
Communication speed 100 Base–TX(100 Mbps/Full Duplex)
Max. number of connected modules 20 (Daisy–chain connection)

RS–485 communication

Protocol Modbus TCP Protocol
Port 1port / Ta, Tb, SG(Shield–Ground)
Connector type Push In conductor 0.13 – 1.5 mm2 (26 – 16 AWG)
Communication cable UL2919 RS–485 1P/2P 24 AWG
Cable length Up to 1,219 m (4000 ft)
Communication speed 1,200 – 115,200 bps9
Max. number of connected modules 32 per bus9
Control Power Supply(Supplied from the POWER Module)
Port name L+, N–, G(Earth Ground)
Connector type Push In conductor (Pluggable)
Wire specification 0.2 – 4.0 mm2 (24 – 12 AWG)
power supply voltage(Us) AC 100 – 240 V 50/60Hz, DC 100 – 300 Vdc
Operating voltage range 0.9 x Us – 1.1 x Us
Withstand voltage AC 2000 V RMS, 60Hz for 1 minute

Power Consumption

Max. 7 W IO module not connected
Max. 15 W10 4 IO modules connected

Inrush current11

Peak 22 A, duration less than 1 msec(AC 220 V)
Peak 11 A, duration less than 200 μsec(DC 110 V)
General
Weight 700 g (including the POWER module)

1. The maximum tightening torque of the terminal screws of the barrier-type terminal is 1.24 Nm (13 kgf-cm, 11 Ibf-in).
2. The maximum tightening torque of the terminal screws of the barrier-type terminal is 1.4 Nm (14 kgf-cm, 12 Ibf-in).
3. The basic voltage Un is 280V
4. The basic current In is 5 A.
5. Peak demand is calculated based on thermal demand. The response time for thermal demand can be set up.
6. For active power demand, Received or Net active power can be selected.
7. The built–in Ethernet switch allows for Ethernet connection between Accura 3700 devices, without a separate external switch.
8. FTP(Foiled Shield Twisted Pair), STP(Braided Shield Twisted Pair), SFTP(Braided Foiled Shield Twisted Pair)
9. Up to 16 devices can be connected per bus at 11,5200 bps.
10. It indicates the maximum power consumption of the connected modules, including Accura 3700 IO module.
11. When installing a fuse at the voltage line, it is recommended to use a fuse above 2A/500V due to inrush current

Sản phẩm cùng loại