Limitorque Valve Network Interface Module for ControlLogix

MVI56-LTQ

The MVI56 Limitorque Valve Actuator Master Network Interface Module allows Rockwell Automation ControlLogix processors to interface easily with Limitorque Valve Actuators and other Limitorque protocol compatible devices.
  • MVI56-LTQ prosoft-
  • Liên hệ
  • 658
  • Thông tin sản phẩm
  • Bình luận

Specifications

  • Implements Limitorque's Port A/B polling scheme using both ports on the LTQ module
  • RS-232 or RS-485 communications (jumper selectable)
  •  Software configuration (from processor ladder logic)
     - Baud rate: 1,200 TO 38,400
     - Message response timeout
     - Number of active slaves: 1 to 150
     - Last state on comm fail
     - Network polling scheme (looped, port 1 only, port 2 only)
    - Active slave table: bit mapped up to 150 slaves)
  •  Supported commands
     - Continuously poll: read registers 40008 - 40013
     - Valve position
     - Status and fault registers
     -Digital outputs and digital
     - Inputs registers1 and 2
    - Communication error code and comm counter)
  •  Commands
    - Open, stop, close, initiate network ESD, terminate network ESD, engage contactors 1 - 6, disengage contactors 1 - 6, valve position (0 - 100%))
  • Support for the storage and transfer of up to 150 valves to the ControlLogix processor's controller tags
  • Emulates Limitorque's Port A/B polling scheme using both ports on the module
  •  Supports the following valves
     
    • MX/DDC Modbus
    • UEC-3-DDC Modbus
    • DDC-100M I/O module
    • DDC-100M field unit
    • Valvcon IVO (unit in multi-drop mode only)
  •  Software configuration
     
    • Baud rate: 1200 to 115200
    • Message response timeout
    • Number of active slaves
    • Last state on communication failure for valve data
    • Network polling scheme
    • Active slave table (bit mapped)
    • Use of CTS module line option
    • Backplane failure affect on communication port availability
  •  Support command
     
    • Continuously polled
    • Read registers 40008 to 40013, optional 40055 or 40006/40007
    • Commands: open, stop, close, initiate network ESD, terminate network ESD, engage contactors 1 to 6, disengage contactors 1 to 6, position valve (0 to 100%)
  •  Data returned to the processor for each valve
     
    • Valve position
    • Status register
    • Fault register
    • Digital outputs
    • Digital inputs registers 1 and 2
    • Communication error code
    • Communication poll counter
    • Special polled registers