Thiết bị đo lưu lượng SLA5851S1DBF1C2A1 Brooks instrument

0944911836 Ms. Duyên 0972835740 Ms. Hà 0385097045 Mr. Hiếu 0392468875 Ms. Anh 0707602728 Ms. Vân
Thiết bị đo lưu lượng SLA5851S1DBF1C2A1 Brooks instrument

Thiết bị đo lưu lượng SLA5851S1DBF1C2A1 Brooks instrument

Model :SLA5851S1DBF1C2A1

Ref. S/N E4368601001

Elastomer, Digital, Gas Mass Flow / Pressure Meters & Controllers

LineDescription SLA5851 CO2 10 KG/H

Base Model SLA5851 REV B

Max Press 1500 psig [103 BAR]

Max Temperature 149F [65C]

Temperature 20C

Meter Material 316L SS

Valve Type NC

Valve Seat PTFE

O-Ring Buna

Elect Conn 15-pin D-Conn

Proc Conn Sz 3/8-in

Conn Type Comp

Fs Flow Rate 10 KG/H

Gas CO2

Inl Pressure 11 barg

Out Pressure 10 barg

Cal Ref Temp N/A

Input Signal 4-20mA

Output Sig 4-20mA

Comm Smart Emulation

Baudrate 19200

OutputEnh Std Response

PwrSplyIn 24 Vdc

Cert Safe Area

Mtg Att [1] Horizontal base down

Calibration [B] Standard Calibration

Oem Cust Standard Brooks label

Orifice Size 0.076

Restrictor Type Sintered

Restrictor Size Size code H

N2 E. Gas Factor 0.74

N2_EQ 113.922724 NLPM

RT Aux Input N/A

Viscosity 0.0141

Density 21.8405 kg/m3

Specific Heat 0.8894 J/g K

Filter None

  • SLA5851S1DBF1C2A1
  • Liên hệ
  • 177
  • Thông tin sản phẩm
  • Bình luận

SLA5800 Series Elastomer Sealed Thermal Mass Flow Controllers & Meters

Advance and simplify your mass flow control.

Models SLA5850 / SLA5851 / SLA5853 / SLA5860 / SLA5861 / SLA5863

Imagine choosing just one mass flow controller platform to handle fourteen different pressure or flow rates going into a single process. All while delivering the exact same, ultra-precise and repeatable output on the other side. That’s the advanced simplicity you get with the SLA5800 Series digital mass flow controllers and meters.

The SLA5800 Series features the high accuracy, high zero stability and high repeatability you expect from the industry leader in mass flow measurement and control technology. Engineered with a superior design - and manufactured with advanced metrology and test systems - the SLA5800 digital MFC offers a better zero drift specification than competitive products. SLA5800 has been proven to maximize production uptime and reduce maintenance and machine downtime costs. 

  SLA5850 SLA5851 SLA5853 SLA5860 SLA5861 SLA5863
Product Type Mass Flow Controller Mass Flow Controller Mass Flow Controller Mass Flow Meter Mass Flow Meter Mass Flow Meter
Differentiator

Controller

Flow Range

Controller

Flow Range

Controller

Flow Range

Meter

Flow Range

Meter

Flow Range

Meter

Flow Range

Flow Range (Full Scale Capacity) 0.003 - 50 slpm 15 - 150 slpm 100 - 2500 slpm 0.003 - 50 slpm 15 - 150 slpm 100 - 2500 slpm
Max Pressure

1500 psi / 103 bar

Optional 4500 psi / 310 bar

1500 psi / 103 bar 1000 psi / 70 bar

1500 psi / 103 bar

Optional: 4500 psi / 310 bar

1500 psi / 103 bar 1000 psi / 70 bar
Accuracy

±0.6% of SP

±0.6% of SP

±0.6% of SP

1100 slpm up to 2500 slpm: ±0.6% of FS

±0.6% of SP

±0.6% of SP

±0.6% of SP

1100 slpm up to 2500 slpm: ±0.6% of FS

Repeatability 0.20% S.P. 0.20% S.P. 0.20% S.P. 0.20% S.P. 0.20% S.P. 0.20% S.P.
Response Time <1 second <1 second <3 seconds <1 second <1 seconds

<3 seconds

Multi-Gas & Range Configurability Standard Standard Standard Standard Standard Standard
Diagnostic Capability

Status Lights - MFC Health , Network Status

Alarms - Sensor Output, control Valve output, Over Temperature, Power Surge/Sag, Network Interruption

Diagnostic/Service Port - RS485 via 2.5 mm jack

Status Lights - MFC Health , Network Status

Alarms - Sensor Output, control Valve output, Over Temperature, Power Surge/Sag, Network Interruption

Diagnostic/Service Port - RS485 via 2.5 mm jack

Status Lights - MFC Health , Network Status

Alarms - Sensor Output, control Valve output, Over Temperature, Power Surge/Sag, Network Interruption

Diagnostic/Service Port - RS485 via 2.5 mm jack

Status Lights - MFC Health , Network Status

Alarms - Sensor Output, control Valve output, Over Temperature, Power Surge/Sag, Network Interruption

Diagnostic/Service Port - RS485 via 2.5 mm jack

Status Lights - MFC Health , Network Status

Alarms - Sensor Output, control Valve output, Over Temperature, Power Surge/Sag, Network Interruption

Diagnostic/Service Port - RS485 via 2.5 mm jack

Status Lights - MFC Health , Network Status

Alarms - Sensor Output, control Valve output, Over Temperature, Power Surge/Sag, Network Interruption

Diagnostic/Service Port - RS485 via 2.5 mm jack

Analog Communication

0-5 Vdc, 1-5 Vdc, 0-10 Vdc, 0-20 mA, 4-20 mA

0-5 Vdc, 1-5 Vdc, 0-10 Vdc, 0-20 mA, 4-20 mA

0-5 Vdc, 1-5 Vdc, 0-10 Vdc, 0-20 mA, 4-20 mA

0-5 Vdc, 1-5 Vdc, 0-10 Vdc, 0-20 mA, 4-20 mA

0-5 Vdc, 1-5 Vdc, 0-10 Vdc, 0-20 mA, 4-20 mA

0-5 Vdc, 1-5 Vdc, 0-10 Vdc, 0-20 mA, 4-20 mA

Digital Communication

DeviceNet™

EtherCAT® 

EtherNet/IP™

FOUNDATIONTM Fieldbus 

Profibus®

PROFINET

RS-485

DeviceNet™

EtherCAT® 

EtherNet/IP™

FOUNDATIONTM Fieldbus 

Profibus®

PROFINET

RS-485

DeviceNet™

EtherCAT® 

EtherNet/IP™

FOUNDATIONTM Fieldbus 

Profibus®

PROFINET

RS-485

DeviceNet™

EtherCAT® 

EtherNet/IP™

FOUNDATIONTM Fieldbus 

Profibus®

PROFINET

RS-485

DeviceNet™

EtherCAT® 

EtherNet/IP™

FOUNDATIONTM Fieldbus 

Profibus®

PROFINET

RS-485

DeviceNet™

EtherCAT® 

EtherNet/IP™

FOUNDATIONTM Fieldbus 

Profibus®

PROFINET

RS-485

Sản phẩm cùng loại