Thiết bị đo mức Hitrol Float Type Level Transmitter HT-100R Series HT-100RS HT-100RSH HT-100RS-Ex HT-100RSH-Ex HT-100RV HT-100RV-Ex HT-100RT HT-100RTH HT-100RT-Ex HT-100RTH-Ex

0944911836 Ms. Duyên 0972835740 Ms. Hà 0385097045 Mr. Hiếu 0392468875 Ms. Anh 0707602728 Ms. Vân
Thiết bị đo mức Hitrol Float Type Level Transmitter HT-100R Series HT-100RS HT-100RSH HT-100RS-Ex HT-100RSH-Ex HT-100RV HT-100RV-Ex HT-100RT HT-100RTH HT-100RT-Ex HT-100RTH-Ex

Thiết bị đo mức Hitrol Float Type Level Transmitter HT-100R Series HT-100RS HT-100RSH HT-100RS-Ex HT-100RSH-Ex HT-100RV HT-100RV-Ex HT-100RT HT-100RTH HT-100RT-Ex HT-100RTH-Ex

Overview

HT-100R Series is a Float Type Level Transmitter which continuously measures the liquid level in the tank by usage of buoyancy. This transmitter can be easily installed and adjusted, and can be especially applied for corrosive and acidic liquids with various anti-corrosive materials such as PVC or Teflon for the sensor. HT-100R Series is extensively used to measure liquid levels in various industries.

Characteristics

- Widely used to measure various liquid levels with high resolution (Resolution 10mm)

- Applicable to corrosive and acidic liquids with anti-corrosive material for the sensor (PVC and Teflon)

- Applicable to explosion area (Ex-Proof version)

- Strong structure and high reliability

- Local Indication is available. (Display Type)

- NAMUR NE43 is applied.
  • Liên hệ
  • 3242
  • Thông tin sản phẩm
  • Bình luận

Operation Principle and Composition

As liquid level is changed in the tank, the float which is manufactured in accordance with the specific gravity of liquid moves upward or downward along the guide pipe with the same liquid level by buoyancy. The magnet is installed in the float and it activates reed switches that are installed in the guide pipe continuously, and activation of reed switches changes the resistance value. The variation of resistance value is transmitted to the R/I converter in the housing and it converts this resistance value to current output of DC 4-20mA continuously.

 

 

 

 

 

 

Specification

 

 

 

Float Application

Note : ◎ = Excellent   ○=Good    △=Acceptable    X=Not good
* Above application can be different according to the specific gravity and the special medium.

 

 

Measuring Length

A = Upper Dead Band : Minimum length which cannot be measured from the bottom of flange 

B = Measuring Range : It can be different according to the material. 

C = Lower Dead Band : Minimum length which cannot be measured from the end of guide pipe

 

*If the measuring length is below than 600mm, the accuracy can be lower than described.

 

 

 

 

 

 

DIGITAL TYPE R/I Converter & RLT

 

 

 

Wiring

- It can be set freely according to user environment.

- Without removing of wire, output value can be checked using the T Terminal.

- Auto Set function (Patent No.: 10-1657573)

- Self-diagnosis Function(Diagnosis of float breakaway and state of sensor)

- Simulation Current Out Function (4mA, 12mA, 20mA)

 

 

■ R/I CONVERTER

◈ + - : DC 24V (DC 4~20mA Loop)
◈ T : Output Test Point
◈ H.C.L : Terminals between Sensor and R/I Converter

- It can be set freely according to user environment.

- Without removing of wire, output value can be checked using the T Terminal.

- Auto Set function (Patent No.: 10-1657573)

- Self-diagnosis Function(Diagnosis of float breakaway and state of sensor)

- Simulation Current Out Function (4mA, 12mA, 20mA)

 

 

■ RLT (Display Type)

◈ + - : DC 24V (DC 4~20mA Loop)
◈ T : Output Test Point
◈ H.C.L : Terminals between Sensor and RLT (Display Type)

 

 

 

 

Dimension

Standard Version

Ex-Proof Version

Display Standard Version

High Temperature Version

High Temperature and Ex-Proof Version

Display High Temperature Version

 

◈ Actual product may have a tolerance slightly.

 

 

 

 

Installation

 

■ Below drawing should be considered when installation.

Product should be installed at the place far from inlet in order to avoid the malfunction.

Protection tube should be applied if there is a flow or slopping of the medium in the tank.

Bracket should be installed with the product when the installation on the concrete as per above figure.

Inner diameter ("d") of tank nozzle should be larger than the outer diameter of float as per above figure. 

Sản phẩm cùng loại