Van điều khiển Co-ax 3/2 Way coaxial Externally Controlled Valves VMK / VFK 20 DR
ports threads G 3/4 - G 1 1/4
flanges PN 16/40/100
function NC
pressure range 0-16 / 0-40 / 0-64 / 0-100 bar
A B max. 100 bar
B A max. 16 bar
A C max. 100 bar
C A max. 100 bar
KV value 8,3 m³/h
media gaseous liquid highly viscous gelatinous pasty contaminated
flow direction see pressure range
switching cycles 200 1/min
switching time opening 50-3000 ms
closing 50-3000 ms
media temperature 60 °C direct mounted pilot valve
ambient temperature 50 °C direct mounted pilot valve
weight VMK 5,8 kg
VFK 7,2 kg
nominal voltage Un 24 V DC
Un 230 V 40-60 Hz AC
protection IP65 (P54) DIN 40 050
energized duty rating ED 100%