Bộ chuyển đổi áp suất Pressure Transducer T200 / T201 Series Anfield Sensors
Accuracy | +/- 0.5 % FS* |
Pressure Range | 0 to 7,500 PSI (517 BAR) |
Proof Pressure | 140% to 200% FS based on range (consult factory) |
Burst Pressure | 180% to – 400% FS based on range (consult factory) |
Wetted Materials | Ceramic Al2O3 |
NBR (Standard) or Optional: FKM,HNBR,EPDM | |
Long Term Drift | < 0.3% FS @ 77°F (25°C) |
Thermal Error | 7.5 psi > 100 psi: 0.01% FS/°F (0.018% FS/°C) |
100 psi > 400 psi : 0.009% FS/°F (0.0016% FS/°C) | |
400 psi >1000 psi: 0.011% FS/°F (0.019% FS/°C) | |
1000 psi > 3000 psi: 0.012% FS/°F (0.021% FS/°C) | |
3000 psi > 7500 psi: 0.018% FS/°F (0.028/% FS/°C) | |
Compensated Temperatures | T200 : 32°F to 257°F (0°C to 85°C) |
T201 : -40°F to 257°F (-40°C to 125°C) | |
Operating Temperatures | -40°F to 257°F (-40°C to 125°C) |
Storage Temperature Rating | -40°F to 257°F (-40°C to 125°C) |
Process Connection | Standard: SS304 |
Vibration | 10g (20-2000Hz) for ≤ 58 PSI (4 BAR) |
20g (20 – 500Hz) for ranges > 58 PSI (4 BAR) | |
Shock | 50g (11ms) |
Output Options | 4 -20 mA (2 wire |
0 – 10 V (3 wire) | |
0.5 – 4.5 V ratio-metric | |
0-5 V (3 wire) | |
1 – 5 V (3 wire) | |
0.5 – 4.5 V (3 wire) | |
1 – 6V (3 wire) | |
0.25 – 10.25 V (3 wire) | |
Supply Voltage for Voltage Output | 4 – 20mA : 8 – 30 VDC |
4 – 20mA : 8 – 30 VDC | |
0 – 10V : 12 – 30 VDC | |
0.5 – 4.5V : 4.5 – 5.5 VDC (ratiometric) | |
0.5 – 4.5V : 8 – 30 VDC | |
0 – 5V : 8 – 30 VDC | |
1 – 5V : 8 – 30 VDC | |
1 – 6V : 9 – 30 VDC | |
0.25 – 10.25 V : 12 – 30 VDC | |
*Other supply voltage available upon request | |
Response Time | < 1ms |
Protection | Overvoltage, Short Circuit, Reverse Polarity Protection |
Ingress Protection | IP67 (IP65 for M2 Electrical Connection) |
Compliance | IEC/EN 61000-4-3(2006) 100V/m 80-1000MHz |
IEC/EN 61000-4-4(2004) Class 3 | |
IEC/EN 61000-4-6(2006) 3Vrms 0.15-80MHz | |
ROHS | |
Weight | 0.15 lbs (0.07kg) |