Cảm biến an toàn sau UST- 50LN HOKUYO-Japan
kinds | Detection area setting type | |
format | UST-05LN | UST-05LA |
product code | UUST101 | UUST102 |
Power-supply voltage | Power supply voltage DC12V/DC24V (operating voltage range 10 to 30V ripple within 10%) | |
current consumption | 150mA or less (when using 24VDC) However, a rush current of approximately 400mA is required at startup | |
light source | Semiconductor laser (905nm) Laser safety class 1 | |
Detection distance and object | 60 mm ~ 5000 mm (White Kent Paper) | |
60mm to 2000mm (at 10% reflectance) | ||
Minimum detectable object 130mm (varies with distance) *1 | ||
Ranging accuracy | 60mm~5000mm±40mm *2 | |
Repeatability | σ<20mm *2 | |
scanning angle | 270 degrees | |
scanning time | 25msec (motor speed 2400rpm) | |
angular resolution | 0.5 degrees | |
Start-up time | Within 10 seconds (However, it may exceed depending on the startup conditions (failure).) | |
output | Output 5 points (photocoupler/open collector output DC30V 50mA MAX.) Output 1: Output OFF when detected within area Output 2: Output OFF when detected within area Output 3: Output OFF when detected within area Output 4: Fault output (normal) Output ON) Output 5: Synchronous output (Note) When a failure output is output, outputs 1 to 3 indicate that there is an obstacle. |
|
input | 6 inputs (photocoupler input, anode common, input ON current 4mA) Inputs 1 to 5: Inputs for switching detection areas Synchronization input: Synchronization signal input for slave units |
|
Response time *3 | OFF: 66msec to 3241msec ON: 66msec to 3241msec |
|
hysteresis | Hysteresis 6.25% hysteresis 3.125% hysteresis None (at shipment) |
|
interface | USB (USB micro-B type connector) | |
RS422 (UST-05LA only) | ||
Indicator light | Power supply indicator (blue): Lights up during operation, flashes during startup/setting and failure Output 1 indicator (orange): Lights up when detected within area Output 2 indicator (orange): Lights up when detected within area Output 3 indicator (Orange): Lights up when detected within the area |
|
Synchronization function | Synchronous operation mode (set by application) *4 Synchronous slave (0°) Synchronous slave (90°) Synchronous slave (180°) Synchronous slave (270°) |
|
Ambient operating temperature/humidity | -10°C to +50°C 85% RH or less (no condensation or freezing) | |
Ambient illumination | Less than 80,000 lx |
|
Vibration resistance | 10 to 55Hz double amplitude 1.5mm X. Y. Z direction each 2 hours 55-200Hz 98m/s 2 sweeps 2 minutes X. Y. 1 hour each in Z direction |
|
shock resistance | 196m/s2 ( 20G) X. Y. 10 times each in the Z direction | |
protection structure | IP65 | |
mass | 130g (excluding cable) |