Receiver: Type: M20E-081A3A221; Part no.: 1018233
Sender: Type: M20S-081A3A220; Part no.: 1018232
Safety-related parameters
Type Type 2 (IEC 61496-1)
Safety integrity level
SIL1 (IEC 61508)
SILCL1 (EN 62061)
Category Category 2 (EN ISO 13849)
Test rate (internal test) 13 /s (EN ISO 13849) 1)
Maximum demand rate ≤ 8 min⁻¹ (EN ISO 13849) 2)
Performance level PL c (EN ISO 13849)
PFHD (mean probability of a dangerous failure per hour) 6.6 x 10-9 (EN ISO 13849)
TM (mission time) 20 years (EN ISO 13849)
Safe state in the event of a fault At least one OSSD is in the OFF state.