Cảm biến đo điểm sương Cosa Xentaur HDT-XTR100 , Model HDT-100, Part: DPT.00.A.1100 COSA XENAUR Model HDT dew point transmitter HDT-100 HDT-60

0944911836 Ms. Duyên 0972835740 Ms. Hà 0385097045 Mr. Hiếu 0392468875 Ms. Anh 0707602728 Ms. Vân
Cảm biến đo điểm sương Cosa Xentaur HDT-XTR100 ,  Model HDT-100, Part: DPT.00.A.1100   COSA XENAUR Model HDT  dew point transmitter  HDT-100 HDT-60

Cảm biến đo điểm sương Cosa Xentaur HDT-XTR100 , Model HDT-100, Part: DPT.00.A.1100 COSA XENAUR Model HDT dew point transmitter HDT-100 HDT-60

Model HDT-100, 2 wire dew point transmitter, -100 deg. C to +20 deg. C dew point range, 4-20 mA output, HART, Digital contact

Part: DPT.00.A.1100.

  • Cosa Xentaur HDT-XTR100
  • Liên hệ
  • 263
  • Thông tin sản phẩm
  • Bình luận

Cảm biến đo điểm sương Cosa Xentaur HDT-XTR100 ,  Model HDT-100, Part: DPT.00.A.1100   COSA XENAUR Model HDT  dew point transmitter

The COSA XENAUR Model HDT  dew point transmitter uses a our HTF high capacitance aluminum oxide sensor with a measuring range of -100ºC to +20ºF or -60ºC to +20ºC. Customers can also request special ranges for special applications. The dew point sensors provide a high degree of accuracy, speed, of response and stability unavailable from instruments using conventional aluminum oxide or polymer sensors.

HART-Compliant Dew Point Transmitter
The HDT is a HART compliant dewpoint transmitter, providing loop powered analog as well as a digital output. Housed in a 32mm dia. Stainless steel housing it has an overall length of 136mm including the Industrial Standard 9.4mm 4-pin connector.

Measurement Accuracy & Stability
The HDT transmitter uses a multipoint calibration table which provides temperature compensated dewpoint readings for temperatures from -10ºC to +70ºC with the option of going below -10ºC. Thus, the HDT provides accurate dewpoint measurements over its full range even under extreme temperature conditions, such as when installed outdoor or close to heat sources.

Features

  • HTF Sensor Technology
  • Small Size
  • Capable of Liquid Hydrocarbon Measurements
  • Programmable Alarm Signal
  • Temperature Compensated Calibration
  • Digital Communications (HART Protocol)
  • Analog Communications (4-20mA)

HDT-100

HDT-100  Loop Powered Dewpoint Meter with XTR-100 sensor, sensor fitting, 2 wire transmitter with HART Interface. FM and ATEX approved for Class 1, Div 1 applications. Range -100ºC to +20ºC    Accuracy: ±3°C (±5.5°F)    

     

HDT-60

HDT-60  Loop Powered Dewpoint Meter with XTR-60 sensor, sensor fitting, 2 wire transmitter with HART Interface. FM and ATEX approved for Class 1, Div 1 applications. Range -60ºC to +20ºC   Accuracy: ±3°C (±5.5°F)                                