Specifications
Sensor type
- Pt1000 Class A Platinum resistance thermometer (PRT)
Sensor connection
Sensor housing
Sensor and cable
Connector
Measurement accuracy
Compliance
- IEC 61724-1:2021, Class A
Number of sensors required
- 3 per monitoring station required, minimum 6 per PV system, depending on the size of the system as per IEC 61724-1
IP protection class
Disk material
Disk diameter
Disk thickness
Insulation resistance
- > 2 GΩ at 1 kV as per IEC 60060-1
Adhesive material
Adhesive thickness
Total heat transfer coefficient
- > 500 W/(m2∙K) as required in IEC 61724-1
Cable length
Cable extension
- to preferred length, should be extended by the user
Cable diameter
Connector type
Cable connector
- 4P or 5P female M12-A connector
Unique features and benefits
- high measurement accuracy
- compliant with requirements of IEC 61724-1 for Class A systems
- disk adhesive rated for prolonged outdoor use
- small surface area to minimise impact on bifacial modules
- thin cable for routing between cells of bifacial modules
- thin cable minimises the mechanical force on the adhesive connecting the sensor to the module
- easily extendable cable
- ingress protection class: IP67