order no.dbk+4/M12/3BEE/M18 E+S
2 x npn
working rangepapers with weights of 20 - 600 g/m2, Washi, metal-laminated sheets and films up to 0.2 mm thick, self-adhesive films
designcylindrical M12 with a swapped-out ultrasonic transducer
operating modedouble sheet control
particularitiesdistance between transmitter and receiver can be selected
swapped-out ultrasonic transducer
M12
cable connection
ultrasonic-specific
means of measurementpulse operation with amplitude evaluation
transducer frequency500 kHz
blind zone5 mm in front of transmitter and receiver
electrical data
operating voltage UB9 - 30 V d.c., reverse polarity protection
voltage ripple± 10 %
no-load current consumption≤ 50 mA
type of connection2 m PUR cable, 7 x 0.25 mm2
transmitter cableam Empfänger: 1,2 m PUR-Kabel, am Sender: 1 m PUR-Kabel, mit M8 Rundsteckverbinder; zum ausgelagerten Empfangswandler: 1,2 m PVC-Kabel
outputs
output 1double sheet output
npn: Imax = 200 mA (-UB+2V)
NOC/NCC adjustable, short-circuit-proof
output 2missing sheet output
npn: Imax = 200 mA (-UB+2V)
NOC/NCC adjustable, short-circuit-proof
response time< 500 µs in trigger mode, 2.5 ms in free-run mode
delay prior to availability< 750 ms
inputs
description< -UB+6 V: logic 1; > -UB+10 V or control input open: logic 0
input 1control input
input 2control input
input 3control input
housing
transmitter/receiver spacing20 - 40 mm; optimal: 20 mm ± 2 mm
permissible angular deviation± 45° from the perpendicular to the sheet
materialbrass sleeve, nickel-plated, plastic parts, PBT, PA
ultrasonic transducerpolyurethane foam, epoxy resin with glass contents
max. tightening torque of nutsM18: 15 Nm, M12: 3 Nm
class of protection to EN 60529IP 65
operating temperature+5°C to +60°C
storage temperature-40°C to +85°C
weight160 g
further versionssingle transmitter/receiver
further versionsdbk+4/Sender/ M12/K1
dbk+4/Empf/M12/3BEE/ M18
technical features/characteristics
controlscontrol input
scope for settingsworking range selection via control inputs
Teach-in via control inputs
LCA-2 with LinkControl
indicators1 x Duo-LED; green: working / red: double sheet / flashing red: missing sheet
particularitiesdistance between transmitter and receiver can be selected
swapped-out ultrasonic transducer
M12
cable connection