Series MSI-SR4B
Application E-Stop circuits
Optoelectronic protective devices
Position switches (mechanical contacts)
Solenoid switches (reed contacts, equivalent)
Transponder switches (OSSD outputs)
Functions Contactor monitoring (EDM)
Cross circuit monitoring
Start/restart interlock (RES)
Restart Automatic
Manual
SIL 3, IEC 61508
SILCL 3, IEC/EN 62061
Performance Level (PL) e, EN ISO 13849-1
MTTFd 73 years, EN ISO 13849-1
PFHD 2,1E-08 per hour
PFHD, nop = 4800 0.0000000014 per hour
PFHD, nop = 28800 0.0000000045 per hour
PFHD, nop = 86400 0.000000015 per hour
Mission time 20 years, EN ISO 13849-1
Category 4, EN ISO 13849-1
STOP category 0, IEC/EN 60204-1
B10d at DC13 (inductive load) 1,000,000 number of cycles
B10d at AC15 (inductive load) 1,400,000 number of cycles
Protective circuit Fuse on switching output, upstream
Switching frequency, max. 3600 switching cycles/h
Continuous current per current path, max. 3 A
Input current, max. 100 mA
External safeguarding for supply circuit 200 mA delay-action
Permissible input line resistance, max. 30 Ω