Role Phase Over-Current & Ground Fault Relay Model IPR-A2 Orion Italia

Role Phase Over-Current & Ground Fault Relay Model IPR-A2 Orion Italia

Role Phase Over-Current & Ground Fault Relay Model IPR-A2 Orion Italia

IPR-A2

Phase Over-Current & Ground Fault Relay

Current Protection Relay IPR-A is designed to protect medium voltage lines against over-current and short circuit scenarios present in line fault or ground fault even under disturbances. Currents are measured throughout current transformers (CT) from each line. The information is internally processed in order to take the current protection actions defined under ANSI, IAC or IEC standard.

Features

CT primary ratio selectable in 5 A steps (10 A to 6000 A)

Line and ground RMS currents measurement

1 trip relay and 2 programmable auxiliary relay

Control power drop or internal fault relay

Digital inputs: 1 breaker status - 3 programmable

Touchpad programming

Breaker operation and trip failure
  • Liên hệ
  • 322
  • Thông tin sản phẩm
  • Bình luận

Applications

 

  • Primary and backup protection for utility feeder, power plants and industrial distribution systems
  •  Protection of transformers, overhead lines, cables and generators
  • Allow the opening of the switch/disconnector within the limits of its capacity, leaving the circuit interruption fuses in the case of short circuit

 

Protection and Functionality

 

  • (46) Negative sequence timed overcurrent
  • (50) Instantaneous over-current
  • (50N/50G) Instantaneous ground over-current
  • (51) Inverse time phase over-current
  • (51N/51G) Inverse time ground over-current
  • (79) Auto-reclosure
  • ANSI, IAC or IEC/BS142 curves included:
  • moderately inverse
  • normal inverse
  • very inverse
  • extremely inverse
  • definite time
  • Overload alarm pickup level
  • Accumulated kA per phase on breaker interruption

 

Features

 
  • CT primary ratio selectable in 5 A steps (10 A to 6000 A)
  • Line and ground RMS currents measurement
  • 1 trip relay and 2 programmable auxiliary relay
  • Control power drop or internal fault relay
  • Digital inputs: 1 breaker status - 3 programmable
  • Touchpad programming
  • Breaker operation and trip failure

Signalling

 
  • LED and LCD display indication
  • Phase and ground current indication
  • Last trip cause and storage of values
  • Indication and storage of fault conditions and their values
  • Threshold LED for 50/50 N, 51/51 N
 

Communication

 
  • Communication port: (1) RS232 and (2) RS485
  • Remote programming of the setpoints
  • Communication Protocol: Modbus RTU