Cyclops 100 L 1F

Temperature Measurement Range:600 to 3000°C

With Bluetooth & USB connectivity.

Spectral response of 0.8 to 1.1µm. 1 Eye Comfort Filter

Cyclops With Standard Accessories:Lens cap, protection window/filter,

battery, wrist strap, USB cable, heat protection jacket

  • LAND AMETEK Cyclops 100 L 1F
  • Liên hệ
  • 280
  • Thông tin sản phẩm
  • Bình luận

Overview

Easy to handle, simple to operate, Cyclops L portable non-contact pyrometers provide precise temperature measurements. Easily take measurements in multiple locations and verify on-line pyrometer readings. Durable, yet light weight construction means you can operate it for hours at a time without fatigue.

Designed for single-handed use, Cyclops L’s high-resolution lens sighting and an ergonomic one-handed use design, make it simple for you to take safe, accurate temperature readings in hostile environments where you will have a spare hand to steady yourself.

With four, trigger-controlled data-logging modes available, Cyclops L stores up to 9,999 readings internally. Later the recorded data can transferred via Bluetooth or USB to a PC running free Cyclops Logger software to view, analyse the temperature readings.

Several models are available for the specific process challenges of liquid metal, high temperature, medium temperature and furnace applications, Cyclops L provide highly accurate temperature measurements for the glasshydrocarbon processingindustrial processing and steel industries.

HIGHLY PORTABLE ACCURACY
Cyclops L function for extended periods, with on-board data storage allowing up to 9,999 measurement points to be recorded inside the thermometer. A rugged instrument jacket protects Cyclops L against harsh conditions.

EASY TO OPERATE
Cyclops L range is easy to use – High quality, Through the Lens (TTL) sighting means that you simply look through the eyepiece and focus the lens on the desired target. A small graticule within the view exactly defines the area that's being measured. Then simply pull the trigger. Switch between four modes for data-logging. Temperature readings are displayed within the eyepiece and simultaneously on a second display panel on the instrument's side. This allows a colleague standing next to you to also view the readings. Wireless Bluetooth data transmission further enhances the Cyclops operation.

UNIQUE ROUTE MANAGEMENT
Ideal for regular monitoring of sites with multiple measurement locations and verifying readings of permanently installed pyrometers,. Free to download Cyclops Logger software provides configurable measurement routes for your process, uploadable to your thermometer. Pre-configured settings include emissivity and window correction for each measurement location.

AMETEK Land’s portable Cyclops L family is available in a range of models.

 

  CO55L Meltmaster C100L  C160L  C390L 
Measurement Range 1000 to 2000 °C / 1832 to 3632 °F  600 to 3000 °C / 1112 to 5432 °F  200 to 1400 °C / 392 to 2552 °F  450 to 1400 °C / 842 to 2552 °F 
Applications Ideal for Molten Metals and
Foundry applications
Steel, Glass, Refractories,
Heat Treating,
Semi-conductors
Steel, Heat Treating such
as welding, tempering,
annealing, and
semi-conductors
Ideal for Reformer and
Heater Tubes, Reheat
Furnaces
  Some applications may be able to use another model than the one specified as ideal, so please contact us to discuss requirements

 

CO55L  C100L  C160L  C390L 
Measurement Range 1000 to 2000 °C / 1832 to 3632 °F  600* to 3000 °C / 1112 to 5432 °F  200 to 1400 °C / 392 to 2552 °F  450 to 1400 °C / 842 to 2552 °F 
Display External backlit LCD display
4-digit LCD in viewfinder 
External backlit LCD display
5-digit LCD in viewfinder 
External backlit LCD display
5-digit LCD in viewfinder 
External backlit LCD display
4-digit LCD in viewfinder 
Measuring Mode Continuous, Peak, Valley and advanced Meltmaster Continuous, Peak, Valley and Average  Continuous, Peak, Valley and Average   Continuous, Peak, Valley and Average  
Data Logging 9999 readings and 9 routes internally; Mobile (4GB standard storage) or PC logger software ( via Bluetooth® or USB connector)
Data Logging Modes Classic, Burst, Latched, Route 
Optical System 9° field of view; eyepiece adjustable -3.75 to +2.5 diopters
Focusing Range Fixed focus, nominally at 5 m / 197 in. from pyrometer body datum 1 m / 39.3 in. to infinity 450 to 620 mm / 17.7 to 24.5 in. and 215 mm / 8.5 in. fixed focus - with optional close-up lens  1 m / 39.3 in. to infinity 460 to 630 mm / 18.1 to 24.8 in. and 217 mm / 8.5 in. fixed focus - with optional close-up lens  1 m / 39.3 in. to infinity 
Minimum Target Size Parallel 28 mm / 1.1 in target spot diameter from lens to 5 m / 197 in  5 mm at 1 m / 0.19 in. at 39.3 in., 1.8 mm / 0.07 in. and 0.4 mm / 0.016 in. - with optional close up lens  5 mm at 1 m / 0.19 in. at 39.3 in., 2.0 mm / 0.08 in. and 0.5 mm / 0.2 in. - with optional close up lens  4.8 mm / 0.19 in. at 101.4 cm, / 39.9 in nominal from the pyrometer body datum 
Spectral Response Nominally 0.55 μm  1 μm with advanced spectral filtering  1.6 μm with advancedspectral filtering  Nominally 3.9 μm 
Emissivity Adjustment 0.10 to 1.20 in 0.01 step graduations 
Response Time 30 ms 30 ms  30 ms  <500 ms (to 98%) 
Display Update Time 0.5 s 
Accuracy <0.5% (K)  ≤0.25% (K)  ± 0.25% C + 2 °C   ±0.5% (K)  
Measurement Resolution 0.1 °C / 1 °F 
Measurement Field of View Fixed Focus  180:1 circular  180:1 circular  180:1 square 
Repeatability <1 °C / 2 °F  ≤1 °C / 2 °F ≤1 °C / 2 °F  ≤1 °C / 2 °F 
Operating Temp. Range 0 to 50 °C / 32 to 122 °F 
Power Requirement One MN1604 / 6LR61 / PP3 Battery or USB 
Output Bluetooth® / USB Connector 
Weight 0.83 kg / 1.8 lb. 
Sealing IP40
Free Data-Logger Software Software available at Cyclops Logger (PC & Mobile)              
Standard Accessories Lens cap, protection window/filter, battery, wrist strap, USB cable, heat protection jacket 
Optional Accessories Waterproof carry case, long eye relief eyepiece  Close-up lenses, waterproof carry case, long eye relief eyepiece, Neutral Density filters: Options 1F or 2F - filters darken the image to provide better image contrast on bright targets, use two for higher temp. applications.  Close-up lenses, waterproof carry case, long eye relief eyepiece  Waterproof carry case, long eye relief eyepiece 