D4C-1224 Công tắc hành trình Omron
Công tắc hành trình Omron
Actuator | Ratings | Standard load | Microload | ||||
---|---|---|---|---|---|---|---|
5 A at 250 VAC, 4 A at 30 VDC | 0.1 A at 125 VAC, 0.1 A at 30 VDC | ||||||
Cable | VCTF oil- resistant cable *1 |
VCTF cable *2 |
SJT(O) cable *3 |
VCTF oil- resistant cable *1 |
VCTF cable *2 |
||
Cable length (m) |
Model | ||||||
Pin plunger | ![]() |
3 | D4C-1201 | D4C-1401 | D4C-1601 | D4C-4201 | D4C-4401 |
5 | D4C-1301 | D4C-1501 | D4C-1701 | D4C-4301 | D4C-4501 | ||
Roller plunger | ![]() |
3 | D4C-1202 | D4C-1402 | D4C-1602 | D4C-4202 | D4C-4402 |
5 | D4C-1302 | D4C-1502 | D4C-1702 | D4C-4302 | D4C-4502 | ||
Crossroller plunger |
![]() |
3 | D4C-1203 | D4C-1403 | D4C-1603 | D4C-4203 | D4C-4403 |
5 | D4C-1303 | D4C-1503 | D4C-1703 | D4C-4303 | D4C-4503 | ||
Roller lever | ![]() |
3 | D4C-1220 | D4C-1420 | D4C-1620 | D4C-4220 | D4C-4420 |
5 | D4C-1320 | D4C-1520 | D4C-1720 | D4C-4320 | D4C-4520 | ||
Roller lever, high-sensitivity |
![]() |
3 | D4C-1224 | D4C-1424 | D4C-1624 | D4C-4224 | D4C-4424 |
5 | D4C-1324 | D4C-1524 | D4C-1724 | D4C-4324 | D4C-4524 | ||
Sealed pin plunger |
![]() |
3 | D4C-1231 | D4C-1431 | D4C-1631 | D4C-4231 | D4C-4431 |
5 | D4C-1331 | D4C-1531 | D4C-1731 | D4C-4331 | D4C-4531 | ||
Sealed roller plunger |
![]() |
3 | D4C-1232 | D4C-1432 | D4C-1632 | D4C-4232 | D4C-4432 |
5 | D4C-1332 | D4C-1532 | D4C-1732 | D4C-4332 | D4C-4532 | ||
Sealed crossroller plunger |
![]() |
3 | D4C-1233 | D4C-1433 | D4C-1633 | D4C-4233 | D4C-4433 |
5 | D4C-1333 | D4C-1533 | D4C-1733 | D4C-4333 | D4C-4533 | ||
Plastic rod | ![]() |
3 | D4C-1250 | D4C-1450 | D4C-1650 | D4C-4250 | D4C-4450 |
5 | D4C-1350 | D4C-1550 | D4C-1750 | D4C-4350 | D4C-4550 | ||
Center roller lever |
![]() |
3 | D4C-1260 | D4C-1460 | D4C-1660 | D4C-4260 | D4C-4460 |
5 | D4C-1360 | D4C-1560 | — | D4C-4360 | D4C-4560 |
Note: 1. Models are available separately with resistance to viscous oils (oil drain holes are provided), but only with
Plunger Models. Add “-M” to the model number (example: D4C-1202 would be D4C-1202-M). Ask your nearest
OMRON representative for details.
2. Switches with variable roller levers are also available. Ask your nearest OMRON representative for details.
*1. Oil-resistant vinyl cabtire cables; approved by EN and IEC.
*2. Ordinary vinyl cabtire cables.
*3. Switches with SJT(O) Cables (cables approved by UL and CSA) are approved by UL and CSA.
Actuator | Ratings | 5 A at 125 VAC | 4 A at 30 VDC | |||
---|---|---|---|---|---|---|
Cable | VCTF oil-resistant cable *1 |
VCTF cable *2 |
VCTF oil-resistant cable *1 |
VCTF cable *2 |
||
Cable length (m) | Model | |||||
Pin plunger | ![]() |
3 | D4C-2201 | D4C-2401 | D4C-3201 | D4C-3401 |
5 | D4C-2301 | D4C-2501 | D4C-3301 | D4C-3501 | ||
Roller plunger | ![]() |
3 | D4C-2202 | D4C-2402 | D4C-3202 | D4C-3402 |
5 | D4C-2302 | D4C-2502 | D4C-3302 | D4C-3502 | ||
Crossroller plunger |
![]() |
3 | D4C-2203 | D4C-2403 | D4C-3203 | D4C-3403 |
5 | D4C-2303 | D4C-2503 | D4C-3303 | D4C-3503 | ||
Roller lever | ![]() |
3 | D4C-2220 | D4C-2420 | D4C-3220 | D4C-3420 |
5 | D4C-2320 | D4C-2520 | D4C-3320 | D4C-3520 | ||
Roller lever, high-sensitivity |
![]() |
3 | D4C-2224 | D4C-2424 | D4C-3224 | D4C-3424 |
5 | D4C-2324 | D4C-2524 | D4C-3324 | D4C-3524 | ||
Sealed pin plunger |
![]() |
3 | D4C-2231 | D4C-2431 | D4C-3231 | D4C-3431 |
5 | D4C-2331 | D4C-2531 | D4C-3331 | D4C-3531 | ||
Sealed roller plunger |
![]() |
3 | D4C-2232 | D4C-2432 | D4C-3232 | D4C-3432 |
5 | D4C-2332 | D4C-2532 | D4C-3332 | D4C-3532 | ||
Sealed crossroller plunger |
![]() |
3 | D4C-2233 | D4C-2433 | D4C-3233 | D4C-3433 |
5 | D4C-2333 | D4C-2533 | D4C-3333 | D4C-3533 | ||
Plastic rod | ![]() |
3 | D4C-2250 | D4C-2450 | D4C-3250 | D4C-3450 |
5 | D4C-2350 | D4C-2550 | D4C-3350 | D4C-3550 | ||
Center roller lever |
![]() |
3 | D4C-2260 | D4C-2460 | D4C-3260 | D4C-3460 |
5 | D4C-2360 | D4C-2560 | D4C-3360 | D4C-3560 |
Note: Ask your nearest OMRON representative for information on Switching with approved international standards.
*1. Oil-resistant vinyl cabtire cables; approved by EN and IEC.
*2. Ordinary vinyl cabtire cables.
Actuator | Ratings | 0.1 A at 125 VAC | 0.1 A at 30 VDC | |
---|---|---|---|---|
Cable | VCTF oil-resistant cable * | VCTF oil-resistant cable * | ||
Cable length (m) | Model | |||
Pin plunger | ![]() |
3 | D4C-5201 | D4C-6201 |
5 | — | D4C-6301 | ||
Roller plunger | ![]() |
3 | D4C-5202 | D4C-6202 |
5 | D4C-5302 | D4C-6302 | ||
Crossroller plunger | ![]() |
3 | D4C-5203 | D4C-6203 |
5 | D4C-5303 | D4C-6303 | ||
Roller lever | ![]() |
3 | D4C-5220 | D4C-6220 |
5 | D4C-5320 | D4C-6320 | ||
Roller lever, high-sensitivity | ![]() |
3 | D4C-5224 | D4C-6224 |
5 | D4C-5324 | D4C-6324 | ||
Sealed pin plunger | ![]() |
3 | — | D4C-6231 |
5 | — | D4C-6331 | ||
Sealed roller plunger | ![]() |
3 | D4C-5232 | D4C-6232 |
5 | D4C-5332 | D4C-6332 | ||
Sealed crossroller plunger | ![]() |
3 | — | D4C-6233 |
5 | — | D4C-6333 | ||
Plastic rod | ![]() |
3 | D4C-5250 | D4C-6250 |
5 | D4C-5350 | D4C-6350 |
Note: Ask your nearest OMRON representative for information on Switching with approved international standards.
* Oil-resistant vinyl cabtire cables; approved by EN and IEC.
Actuator | Ratings | 1 A at 125 VAC | 1 A at 30 VDC | ||
---|---|---|---|---|---|
Operation indicator |
Without operation indicator |
With operation indicator |
Without operation indicator |
With operation indicator |
|
Pin plunger | ![]() |
— | — | — | D4C-3001-DK1EJ[] |
Roller plunger | ![]() |
D4C-1002-AK1EJ[] | D4C-2002-AK1EJ[] | D4C-1002-DK1EJ[] | D4C-3002-DK1EJ[] |
Sealed plunger | ![]() |
— | — | — | D4C-3031-DK1EJ[] |
Sealed roller plunger |
![]() |
— | — | D4C-1032-DK1EJ[] | D4C-3032-DK1EJ[] |
Roller lever (high-sensitivity model) |
![]() |
— | D4C-2024-AK1EJ[] | D4C-1024-DK1EJ[] | D4C-3024-DK1EJ[] |
Note: 1. The [] contains the length of the cable.
For example: 30 cm → D4C-2002-AK1EJ03
2. M1J models are also available. Contact your OMRON sales representative for further information.
3. Of the above model numbers, some with special specifications are not registered.
Actuator | Operation indicator | Without operating indication | With operating indication | |||
---|---|---|---|---|---|---|
Ratings | Standard load | Microload | Standard load | |||
5 A at 250 VAC 4 A at 30 VDC |
0.1 A at 125 VAC 0.1 A at 30 VDC |
5 A at 125 VAC | 4 A at 30 VDC | |||
VCTF oil-resistant cable * | ||||||
Cable length (m) | Model | |||||
Roller lever | ![]() |
3 | D4C-1220-P | D4C-4220-P | D4C-2220-P | D4C-3220-P |
5 | D4C-1320-P | — | — | — | ||
Roller lever (high-sensitivity model) |
![]() |
3 | D4C-1224-P | D4C-4224-P | D4C-2224-P | D4C-3224-P |
5 | D4C-1324-P | D4C-4324-P | D4C-2324-P | D4C-3324-P | ||
Adjustable roller lever | ![]() |
3 | D4C-1227-P | D4C-4227-P | D4C-2227-P | D4C-3227-P |
5 | D4C-1327-P | D4C-4327-P | D4C-2327-P | D4C-3327-P | ||
Adjustable rod lever | ![]() |
3 | D4C-1229-P | D4C-4229-P | — | D4C-3229-P |
5 | D4C-1329-P | — | D4C-2329-P | D4C-3329-P |
* Vinyl cabtire cable with excellent oil resistance.
Note: Silicon rubber is used to increase resistance to the environment. Silicon rubber, however, can generate silicon gas.
(This can occur at room temperature, but the amount of silicon gas generated increases at higher temperatures.)
Silicon gas will react as a result of arc energy and form silicon oxide (SiO2). If silicon oxide accumulates on the
contacts, contact interference can occur and can interfere with the device. Before using a Switch, test it under actual
application conditions (including the environment and operating frequency) to confirm that no problems will occur in
actual.
Type | For AC | For DC | ||
---|---|---|---|---|
Appearance | No. of conductors | Cable length | Model | Model |
Straight
|
4 | 2 m | XS2F-A421-D90-F | XS2F-D421-D80-F |
5 m | XS2F-A421-G90-F | XS2F-D421-G80-F |
The WL/WL-N model incorporated by equipment can be replaced with the D4C together with the Mounting Plate without changing the position of the dog or cam.
WL/WL-N model (Actuator) | D4C model (Actuator) | Plate |
---|---|---|
WLD/WL01D/WLD18-N (Top plunger) |
D4C-[][]01 (Plunger) |
D4C-P001 |
WLD2/WL01D2/WLD28-N (Top roller plunger) |
D4C-[][]02 (Roller plunger) |
D4C-P002 |
WLCA2/WL01CA2/WLCA2-N (Roller lever) |
D4C-[][]20 (Roller lever) |
D4C-P020 |
Note: The WL01[] is for micro loads.
Note: The position of the dog remains unchanged.
Actuator | Head (with actuator) | Actuator |
---|---|---|
Pin plunger | D4C-0001 | — |
Roller plunger | D4C-0002 | — |
Crossroller plunger | D4C-0003 | — |
Roller lever | D4C-0020 | WL-1A100 |
Roller lever (weather-resistant model) | — | WL-1A100P1 |
Roller lever (high-sensitivity model) | D4C-0024 | WL-1A100 |
Variable roller lever | D4C-0027 | — |
Variable rod lever | D4C-0029 | HL-1HPA500 |
Sealed pin plunger | D4C-0031 | — |
Sealed roller plunger | D4C-0032 | — |
Sealed crossroller plunger | D4C-0033 | — |
Plastic rod | D4C-0050 | — |
Center roller lever | D4C-0060 | — |
Note: 1. The model numbers for heads are of the form D4C-00[][], with the numbers in the squares indicating the type of
actuator.
2. Actuators for plunger models, plastic rod models, and center roller lever models cannot be ordered individually.
They must be ordered together with the head.